Considerations against a force compensated coil
نویسندگان
چکیده
منابع مشابه
3-D RF Coil Design Considerations for MRI
High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...
متن کاملStatic Coil Design Considerations for the Magnetic Resonance Imaging
One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...
متن کاملDesign of a Force-Free Inductive Storage Coil
Force-free coils have been considered for various applications as energy storage devices. A novel energy storage system consisting of both toroidal and poloidal coils has been developed. In this system, the Lorentz forces on the two coils are in opposition and can be made to cancel by having the proper ratio of ampere-turns in the two coils. A general discussion of force-free coil design is giv...
متن کاملMarker alignment for Guglielmi detachable coil embolization: practical considerations.
BACKGROUND AND PURPOSE Aneurysm embolization is not without risk: numerous technical aspects are considered before, during, and after the procedure. The purpose of this study was to show the position of the detachment zone of a Guglielmi detachable coil (GDC) with respect to the catheter tip for various microcatheters and marker alignments. METHODS Six types of commonly used microcatheters we...
متن کاملForce characteristics of nickel-titanium open-coil springs.
INTRODUCTION The objective of this study was to quantify the properties of commercially available nickel-titanium open-coil springs. METHODS Eleven springs from 3 manufacturers were tested 5 times over a 12-week period. A universal testing machine was used to measure the force generated when open-coil springs were compressed to half of their original length and then gradually allowed to decom...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Magnetics
سال: 1989
ISSN: 0018-9464
DOI: 10.1109/20.92665