CONSIDERATIONS ON DRAWING OF PLASTIC TUBES WITH A CONICAL MANDREL

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Upper Bound Analysis of Tube Extrusion Process Through Rotating Conical Dies with Large Mandrel Radius

In this paper, an upper bound approach is used to analyze the tube extrusion process through rotating conical dies with large mandrel radius. The material under deformation in the die and inside the container is divided to four deformation zones. A velocity field for each deformation zone is developed to evaluate the internal powers and the powers dissipated on all frictional and velocity disco...

متن کامل

The Comparison of Glass EDTA Versus Plastic EDTA Blood-Drawing Tubes for Complete Blood Count

Blood-drawing tubes made from plastic containing K2EDTA as an anticoagulant are gaining widespread use in clinical hematology. In this study it is compared complete blood count parameters, white blood cell differentials and flagging rates obtained with Becton Dickinson Vacutainer K3EDTA glass tubes and Vacutainer K2EDTA Plus plastic tubes and found only slight discrepancies in the results obtai...

متن کامل

Experimental and Numerical Simulation Investigation on Crushing Response of Foam-Filled Conical Tubes Stiffened with Annular Rings

In this paper, crashworthiness characteristics of conical steel tubes stiffened by annular rings and rigid polyurethane foam are investigated. For this purpose, wide circumferential rings are created from the outer surface of the conical tube at some determined areas along tube length. In fact, this method divides a long conical tube into several tubes of shorter length. When this structure is ...

متن کامل

Considerations in Dynamic Graph Drawing: A Survey

In this survey paper we discuss the considerations involved in modeling, visualising and exploring dynamic graphs—those graphs which are continually changing in structure to reflect the evolution of the system they are representing. The design of algorithms to analyse and generate visualisations of dynamic graphs pose both a technical and perceptual problem. A range of additional issues beyond ...

متن کامل

Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes

INTRODUCTION Sample type recommended by the manufacturer for the digoxin Abbott assay is either serum collected in glass tubes or plasma (sodium heparin, lithium heparin, citrate, EDTA or oxalate as anticoagulant) collected in plastic tubes. In our hospital samples are collected in plastic tubes. Our hypothesis was that the serum sample collected in plastic serum tube can be used interchangeabl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sen'i Gakkaishi

سال: 1983

ISSN: 0037-9875,1884-2259

DOI: 10.2115/fiber.39.8_t326