Consistent trilayer biomechanical modeling of aortic valve leaflet tissue
نویسندگان
چکیده
منابع مشابه
Echo diagnosis of ruptured aortic valve leaflet.
artery, and it has been suggested that these patients should be treated by bypass surgery. The mechanism for sudden death is not known. Theories include kinking of the anomalous artery2 and occlusion by a flap-like closure of the ostium as the aorta expands.3 However, sudden death, infarction, and ischemia may occur without regard to the course of the anomalous left coronary artery.4 In the pas...
متن کاملAortic Valve Leaflet Motion during Systole
An approximate numerical^graphical solution was made for the motion of a human aortic valve leaflet in a meridional plane through the center of the sinus of Vabalva. The observed buckling, whipping action of the leaflet was obtained. Of primary significance in the results was the location and the determination of the maximum curvature of the leaflet in this plane, since this point corresponds t...
متن کاملPolytetrafluoroethylene leaflet extensions for aortic valve repair.
(Leipzig, Germany): I commend you for your courage in using a new product designed for a completely different purpose, but which works well. My first question is, what are your indication criteria because you have patients with a moderate stenosis and moderate insufficiency, a mean of 1.8 and a mean gradient of 54? Dr Nosál': Typically our patients have a mixed aortic valve pathology, so the me...
متن کاملAortic valve leaflet perforation after mitral valve repair.
A 32-year-old patient with symptomatic severe aortic regurge, 6 weeks after mitral valve repair, was admitted for aortic valve surgery. No preoperative clinical data consistent with infective endocarditis could be detected. Preoperative transthoracic echocardiography showed aortic leaflet perforation affecting non coronary cusp. During operation, leaflet perforation was detected and closed comp...
متن کاملDefining biomechanical endpoints for tissue engineered heart valve leaflets from native leaflet properties
The design and development of functional engineered tissues is dependent on multiple considerations, with biomechanics paramount for load-bearing constructs such as tissue engineered heart valves. As the cryopreserved allograft is the current standard for valve replacement in pediatric patients, identifying and quantifying essential structural–mechanical properties of the native valve leaflet i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Biomechanics
سال: 2017
ISSN: 0021-9290
DOI: 10.1016/j.jbiomech.2017.06.014