Consumption of platelet during cardiopulmonary bypass with membrane oxygenator.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scavenging anesthetic gas from a membrane oxygenator during cardiopulmonary bypass.

Concerns remain about the acute and chronic effects on personnel of waste anesthetic gases in the operating room environment. This study demonstrates a simple and effective means of scavenging waste anesthetic gases when halogenated anesthetics are administered through the pump oxygenator during cardiopulmonary bypass. This technique safeguards workers' health by reducing ambient anesthetic lev...

متن کامل

Evolution of membrane oxygenator technology for utilization during pediatric cardiopulmonary bypass

The development of the membrane oxygenator for pediatric cardiopulmonary bypass has been an incorporation of ideology and technological advancements with contributions by many investigators throughout the past two centuries. With the pursuit of this technological achievement, the ability to care for mankind in the areas of cardiac surgery has been made possible. Heart disease can affect anyone ...

متن کامل

Membrane oxygenator exhaust capnography for continuously estimating arterial carbon dioxide tension during cardiopulmonary bypass.

Typically, the standard practice for measuring the arterial blood carbon dioxide tension (PaCO2) during cardiopulmonary bypass (CPB) is to take intermittent blood samples for analysis by a bench blood gas analyzer. Continuous inline blood gas monitors are available but are expensive. A potential solution is the capnograph, which was evaluated by determining how accurately the carbon dioxide ten...

متن کامل

The effects of cardiopulmonary bypass with hollow fiber membrane oxygenator on blood clotting measured by thromboelastography.

In cardiac surgical patients we investigated the effects of cardiopulmonary bypass (CPB) with a hollow fiber membrane oxygenator on blood clotting measured by thromboelastography (TEG). We found only a minimal change in the strength of blood clot described either by the TEG parameter MA (maximum amplitude) or by the shear modulus G calculated from MA. After CPB there was also a significant tend...

متن کامل

Successful management of membrane oxygenator failure during cardiopulmonary bypass--the importance of safety algorithm and simulation drills.

With a high risk to time ratio, the advent of cardiopulmonary bypass has facilitated greater advances in technical procedures in cardiac surgery. This, however, has not come without its own complication risk and previous near misses have been reported with regard to various technical aspects of the cardiopulmonary bypass circuit. We present a case of a failed membrane oxygenator and discuss the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Blood & Vessel

سال: 1985

ISSN: 0386-9717,1884-2372

DOI: 10.2491/jjsth1970.16.490