Continuous Glucose Sensor Survival and Accuracy Over 14 Consecutive Days

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous Glucose Sensor Survival and Accuracy Over 14 Consecutive Days

Continuous glucose monitoring (CGM) technology provides real-time glucose data and the ability to achieve improved glycemic control; however, widespread adoption has been limited (1). Among the challenges to CGMuptake are cost and the inconvenience of changing the sensor. In this prospective, multicenter study, theDexcomG4PLATINUMsystemwas analyzed over 14 days of continuous sensor wear. Each s...

متن کامل

Continuous glucose monitoring in the subcutaneous tissue over a 14-day sensor wear period.

BACKGROUND Glucose monitoring systems using subcutaneously inserted sensors are currently labeled for up to 7 days of wear. In this study, we evaluated the feasibility of a 14-day wear duration using a modified version of the sensor found in the Freestyle Navigator™ continuous glucose monitoring system. METHODS Sixty-two subjects with diabetes were enrolled in the study. One sensor per subjec...

متن کامل

Accuracy of a Fourth-Generation Subcutaneous Continuous Glucose Sensor

BACKGROUND This study evaluated the accuracy and performance of a fourth-generation subcutaneous glucose sensor (Guardian™ Sensor 3) in the abdomen and arm. METHODS Eighty-eight subjects (14-75 years of age, mean ± standard deviation [SD] of 42.0 ± 19.1 years) with type 1 or type 2 diabetes participated in the study. Subjects wore two sensors in the abdomen that were paired with either a Mini...

متن کامل

Caffeine and performance over consecutive days of simulated competition.

PURPOSE Performance improvements after caffeine (CAF) ingestion are well documented when using a 1-d protocol. In numerous competitions such as the Tour de France, Tour de Ski, world championships, and National College Athletic Association championships, athletes compete for several days in a row. To date, no studies have investigated the effects of CAF when competing for consecutive days in a ...

متن کامل

Accuracy and acceptability of the 6-day Enlite continuous subcutaneous glucose sensor.

OBJECTIVE This study evaluated the performance and acceptability of the Enlite(®) glucose sensor (Medtronic MiniMed, Inc., Northridge, CA). SUBJECTS AND METHODS Ninety adults with type 1 or type 2 diabetes wore two Enlite sensors on the abdomen and/or buttock for 6 days and calibrated them at different frequencies. On Days 1, 3, and 6, accuracy was evaluated by comparison of sensor glucose va...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Diabetes Care

سال: 2016

ISSN: 0149-5992,1935-5548

DOI: 10.2337/dc16-0796