Continuous oxygen saturation monitoring following rectal methohexitone induction in paediatric patients

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous oxygen saturation monitoring during cardiac catheterization in adults.

Arterial hypoxemia may contribute to morbidity during cardiac catheterization. Therefore, we measured arterial hemoglobin oxygen saturation (SaO2) continuously using pulse oximetry in 29 patients (age range, 21 to 83 years) undergoing cardiac catheterization. Baseline SaO2 was 96 +/- 0.4 percent. All patients had a decrease in SaO2 at some time during the procedure. Eleven patients (38 percent)...

متن کامل

Clinical accuracy of continuous hemoglobin oxygen saturation monitoring devices.

Three devices used to measure hemoglobin oxygen saturation in the extracorporeal circuit were studied and compared to a control. The Baxter Bentley OxySat, Oximetrix Accusat, and Radiometer ABL4 blood gas monitor were compared to a control, the IL 282 Co-Oximeter. Fifty-one sample points were obtained during all phases of cardiopulmonary bypass with results as follows: table: see text. The Ac...

متن کامل

Continuous monitoring of mixed venous oxygen saturation during aortic surgery.

The correlation between mixed venous oxygen saturation (SvO2) and hemodynamic measurements was studied in 13 patients undergoing descending thoracic aortic aneurysm resection (DTAAR). A significant correlation (p less than 0.05) was found between cardiac index (CI) and SvO2 after the induction of anesthesia and at the end of surgery. However, no significant correlation could be found between Sv...

متن کامل

Continuous monitoring of mixed venous oxygen saturation in hemodynamically unstable patients.

A balloon-tipped catheter has recently become available which, when placed in the pulmonary artery, in addition to enabling the usual measurements of pulmonary arterial pressure, pulmonary capillary wedge pressure, and cardiac output by thermodilution, measures mixed venous oxygen saturation (SvO2) by spectrophotometry. Unlike the measurement of cardiac output by thermodilution, which is done i...

متن کامل

Validation of Oxygen Saturation Monitoring In

www.ajcconline.org • BACKGROUND Pulse oximetry is commonly used to monitor oxygenation in neonates, but cannot detect variations in hemoglobin. Venous and arterial oxygen saturations are rarely monitored. Few data are available to validate measurements of oxygen saturation in neonates (venous, arterial, or pulse oximetric). • PURPOSE To validate oxygen saturation displayed on clinical monitors ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Canadian Journal of Anaesthesia

سال: 1992

ISSN: 0832-610X,1496-8975

DOI: 10.1007/bf03008668