Control of Closed Orbit Deviation Due to Synchrotron Radiation
نویسندگان
چکیده
منابع مشابه
Orbit Control at Synchrotron Light Sources
Modern synchrotron light sources are pushing the limits of storage ring performance. Precise control of the electron beam orbit is critical for achieving design goals in these machines. A review of closed orbit control will be given, including an overview of the sources of orbit motion, a description of closed orbit correction and feedback algorithms, and a discussion of the pitfalls and limita...
متن کاملBeam Instability and Microbunching due to Coherent Synchrotron Radiation
A relativistic electron beam moving in a circular orbit in free space can radiate coherently if the wavelength of the synchrotron radiation exceeds the length of the bunch. In accelerators coherent radiation of the bunch is usually suppressed by the screening effect of the conducting walls of the vacuum chamber [1, 2]. The screening effect is weak for short wavelengths, but if the wavelength is...
متن کاملSynchrotron Radiation and Pretzeled Orbits Geometry of Synchrotron Radiation Illumination
Turning on a `pretzel' , or any closed orbit distortion, can substantially alter the path of synchrotron radiation (SR), in some instances causing it to strike components not designed to absorb the radiation. In this paper I develop equations useful in determining the source position and angle of dipole SR as a function of the pretzel amplitude and angle. Formula for linear power deposition and...
متن کاملGlycoscience@Synchrotron: Synchrotron radiation applied to structural glycoscience
Synchrotron radiation is the most versatile way to explore biological materials in different states: monocrystalline, polycrystalline, solution, colloids and multiscale architectures. Steady improvements in instrumentation have made synchrotrons the most flexible intense X-ray source. The wide range of applications of synchrotron radiation is commensurate with the structural diversity and compl...
متن کاملSubmitted to Journal of Synchrotron radiation
Scanning X-ray Microdiffraction (μ-SXRD) combines the use of high brilliance synchrotron sources with the latest achromatic X-ray focusing optics and fast large area 2D-detector technology. Using white beams or a combination of white and monochromatic beams, it allows for orientation and strain/stress mapping of polycrystalline thin films with submicron spatial resolution. The technique is desc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1975
ISSN: 0018-9499
DOI: 10.1109/tns.1975.4328026