Controlled ventilation with the Bain co-axial system
نویسندگان
چکیده
منابع مشابه
Spontaneous ventilation with the Bain anaesthetic system.
Measurements of ventilation and of inspired gas composition were made while volunteers breathed a non-anaesthetic gas through a Bain anaesthetic system. It was found that rebreathing occurred when the fresh gas flow was between two-and-a-half and three times the minute volume. Fresh gas flows at least three times the minute volume appear to be necessary to prevent rebreathing when using this sy...
متن کاملComparison of the Bain and the ADE systems during controlled ventilation in adults.
It has been suggested that Humphrey's ADE system may be an improvement on the Bain system. To compare their efficiencies we have studied 20 anesthetized adults who had controlled ventilation established with a circle absorber system at a VE sufficient to maintain normocapnia. Patients were then randomly allocated to either a Bain or an ADE system. Fresh gas flow was sufficient to keep PE'CO2 co...
متن کاملSmall animal ventilation using a co-axial circuit.
A method is presented for the ventilation of small animals using standard adult anaesthetic equipment.
متن کاملVolume-guaranteed Ventilation Versus Pressure-controlled Ventilation in Preterm Infants with Respiratory Distress Syndrome: A Randomized Controlled Trial
Background: This study was targeted toward comparing volume-guaranteed (VG) ventilation with conventional pressure-controlled (PC) ventilation in preterm infants with respiratory distress syndrome (RDS) in terms of the facilitation of weaning and extubation and occurrence of complications, such as pneumothorax, intraventricular hemorrhage (IVH), retinopathy of prematur...
متن کاملAdequacy of preoperative safety checks of the Bain breathing system.
Effects of posture and baricity on spinal anaesthesia with 0.5% bupivacaine 5 ml. Spinal anaesthesia with 0.5 % bupivacaine 3 ml: comparison of plain and hyperbaric solutions administered to seated patients. POSTDURAL PUNCTURE HEADACHE Sir,—We read with interest the article by Lynch and colleagues [1] comparing the incidence of postdural puncture headaches (PDPH) associated with 22-gauge and 25...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Anaesthesia
سال: 2007
ISSN: 0003-2409,1365-2044
DOI: 10.1111/j.1365-2044.1993.tb07531.x