Cooling Design of X-Ray CT Scanner Using Flow Visualization
نویسندگان
چکیده
منابع مشابه
The effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...
متن کاملDesign of Air Distribution System for Operation Theatre Using Flow Visualization Techniques to Improve Flow Characteristics
Operation Theatre (OT) is the most important area where precise controlled on indoor air quality is required because it is directly related to patient health and its recovery period. This work aims to study and visualize the airflow distribution of conventional flat air diffuser ventilation system and newly designed angular air ventilation system in OT. Angular Air Distribution (AAD) system is ...
متن کاملInvestigation of dosimetric characteristic of NIPAM polymer gel using x-ray CT
Introduction: Polymer gel dosimeters contain chemical materials sensitive to the radiation which are polymerized by the radiation as a function of absorbed dose. So information of spatial dose distribution can be extracted by imaging from irradiated gel. Among imaging techniques, computed tomography (CT) poses as an attractive method because of practical advantages such as acce...
متن کاملRosat X-ray Observations of the Cooling Flow Cluster A2597
The cluster A2597 was observed in X-rays with the ROSAT PSPC and HRI detectors. The X-ray emission from the cluster extends out to a radius of at least 2.37 Mpc. The X-ray isophotes are oriented similarly to the optical isophotes of the central cD galaxy and to the isopleths of the galaxy distribution in the cluster, but are otherwise quite regular, suggesting that this cluster is reasonably re...
متن کاملthe effect of focal spot size on the spatial resolution of variable resolution x-ray ct scanner
background: a variable resolution x-ray (vrx) ct scanner provides a great increase in the spatial resolution. in vrx ct scanners, the spatial resolution of the system and its field of view (fov) can be changed according to the object size. one of the main factors that limit the spatial resolution of vrx ct scanner is the effect of the x-ray focal spot. materials and methods: a theoretical study...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Visualization Society of Japan
سال: 2001
ISSN: 1884-037X,0916-4731
DOI: 10.3154/jvs.21.91