Coplanar Electrode Layout Optimized for Increased Sensitivity for Electrical Impedance Spectroscopy

This work describes an improvement in the layout of coplanar electrodes for electrical impedance spectroscopy. We have developed, fabricated, and tested an improved electrode layout, which improves the sensitivity of an impedance flow cytometry chip. The improved chip was experimentally tested and compared to a chip with a conventional electrode layout. The improved chip was able to discriminat...

متن کامل

Characterization of coplanar electrode structures for microfluidic-based impedance spectroscopy

Impedance spectroscopy has the potential for label-free integrated electrochemical detection in microfluidic lab-on-a-chip applications. Its capability to identify and discern between surface and bulk processes in solid-liquid systems finds particular use for the detection of biorecognition events or conductivity measurements. The electrochemical transducer can be in the form of interdigitated ...

متن کامل

Using electrochemical impedance spectroscopy of salicylate anion selective electrode: simulation for behavior of electrode

In this paper, the behavior of the salicylate anion-selective electrode was studied using the electrochemical impedance spectroscopy technique. Considering the diagram of the charge transfer resistance and -logarithm of the double layer capacitance versus -logarithm of the concentration, linear range concentration increased to 1.0×10^{-8}-1.0×10^{-1} M and 1.0×10^{-9}-1.0×10^{-1} M, respectivel...

متن کامل

Multi-electrode systems for electrical impedance tomography.

A wide range of electrode system designs is reviewed for their possible use in UT

متن کامل

Reducing Impedance Fluctuation by Electrode Structure for Electrochemical Impedance Spectroscopy

In this paper, we investigated the electrode structure of the electrical bio-sensor to reduce impedance measurement fluctuation. Five pairs of the same electrodes were formed on the PCB substrate, and a fluidic channel was constructed with a double-sided tape and polycarbonate cover so that all the electrodes had the same reagent distribution. In order to find an electrode structure with little...