Core-Temperature Sensor Ingestion Timing and Measurement Variability

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of sensor ingestion timing on consistency of temperature measures.

PURPOSE The validity and the reliability of using intestinal temperature (T int) via ingestible temperature sensors (ITS) to measure core body temperature have been demonstrated. However, the effect of elapsed time between ITS ingestion and T int measurement has not been thoroughly studied. METHODS Eight volunteers (six men and two women) swallowed ITS 5 h (ITS-5) and 29 h (ITS-29) before 4 h...

متن کامل

Measurement of Temperature, Humidity and Strain Variation Using Bragg Sensor

Measurement and monitoring of temperature, humidity and strain variation are very requested in great fields and areas such as structural health monitoring (SHM) systems. Currently, the use of fiber Bragg grating sensors (FBGS) is very recommended in SHM systems due to the specifications of these sensors. In this paper, we present the theory of Bragg sensor, therefore we try to measure the effic...

متن کامل

Temperature sensor based on double core optical fibre

We report the theoretical and experimental study of a temperature sensor based on the changing of the refractive index with the temperature in double core optical fibre. Because of it the coupling coefficient between two cores depends on temperature. This sensor uses the double core fibre directly as a temperature sensor as well to a data transmission. The influence of variations of the tempera...

متن کامل

Non-invasive continuous core temperature measurement by zero heat flux.

Reliable continuous core temperature measurement is of major importance for monitoring patients. The zero heat flux method (ZHF) can potentially fulfil the requirements of non-invasiveness, reliability and short delay time that current measurement methods lack. The purpose of this study was to determine the performance of a new ZHF device on the forehead regarding these issues. Seven healthy su...

متن کامل

Accuracy of core temperature measurement in deep hypothermic circulatory arrest.

Deep hypothermia is an effective technique for neuroprotection in cardiac surgery. However, standard body temperature measurement may deviate from actual brain temperature. Therefore, we simultaneously measured brain and core temperatures during neurosurgical interventions in hypothermic circulatory arrest to determine its accuracy. Between 1994 and May 2007, 26 patients (12 female, mean age 46...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Athletic Training

سال: 2010

ISSN: 1062-6050

DOI: 10.4085/1062-6050-45.6.594