CORR Insights®: Is There a Difference in TKA Risk of Revision in Highly Crosslinked versus Conventional Polyethylene?

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wear of highly crosslinked polyethylene acetabular components

BACKGROUND AND PURPOSE Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the i...

متن کامل

Is There a Benefit to Highly Crosslinked Polyethylene in Posterior-stabilized Total Knee Arthroplasty? A Randomized Trial.

BACKGROUND Polyethylene wear and osteolysis remain a concern with the use of modular, fixed-bearing total knee arthroplasty (TKA). A variety of highly crosslinked polyethylenes (XLPs) have been introduced to address this problem, but there are few data on the results and complications of this polyethylene in posterior-stabilized knee prostheses. QUESTIONS/PURPOSES In a randomized prospective ...

متن کامل

Outcome in design-specific comparisons between highly crosslinked and conventional polyethylene in total hip arthroplasty

Background and purpose - Most registry studies regarding highly crosslinked polyethylene (XLPE) have focused on the overall revision risk. We compared the risk of cup and/or liner revision for specific cup and liner designs made of either XLPE or conventional polyethylene (CPE), regarding revision for any reason and revision due to aseptic loosening and/or osteolysis. Patients and methods - Usi...

متن کامل

Ground versus earth, there is a difference.

Investigations of injuries and fires caused by electrical circuits and equipment can result in incorrect conclusions when grounding systems are neglected. The term ground is loosely used in electrical jargon as any zero reference point for voltage measurement. Power systems are usually grounded to the earth. Other electrical systems are sometimes grounded to the same earth through a low impedan...

متن کامل

CORR Insights®: Length of Endoprosthetic Reconstruction in Revision Knee Arthroplasty Is Associated With Complications and Reoperations.

BACKGROUND Complex revision total knee arthroplasty (TKA) often calls for endoprosthetic reconstruction to address bone loss, poor bone quality, and soft tissue insufficiency. Larger amounts of segmental bone loss in the setting of joint replacement may be associated with greater areas of devascularized tissue, which could increase the risk of complications and worsen functional results. QUES...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Orthopaedics & Related Research

سال: 2015

ISSN: 0009-921X

DOI: 10.1007/s11999-015-4145-9