Correcting partial volume artifacts of the arterial input function in quantitative cerebral perfusion MRI

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correcting partial volume artifacts of the arterial input function in quantitative cerebral perfusion MRI.

To quantify cerebral perfusion with dynamic susceptibility contrast MRI (DSC-MRI), one needs to measure the arterial input function (AIF). Conventionally, one derives the contrast concentration from the DSC sequence by monitoring changes in either the amplitude or the phase signal on the assumption that the signal arises completely from blood. In practice, partial volume artifacts are inevitabl...

متن کامل

Quantitative MRI of Cerebral Arterial Blood Volume

Baseline cerebral arterial blood volume (CBV(a)) and its change are important for potential diagnosis of vascular dysfunctions, the determination of functional reactivity, and the interpretation of BOLD fMRI. To quantitative measure baseline CBV(a) non-invasively, we developed arterial spin labeling methods with magnetization transfer (MT) or bipolar gradients by utilizing differential MT or di...

متن کامل

Quantitative myocardial perfusion imaging using a step arterial-input function

Background Modern MRI myocardial perfusion protocols use rapid venous bolus injections, typically 3-5 ml/s of 5-15 ml of agent over a few seconds. The resulting arterial input functions are rapidly varying with high agent concentrations (Fig. 1A and 1B) and thus typically require high temporal resolution acquisitions (~1 sec), custom pulse sequences and complex processing methods for perfusion ...

متن کامل

Correcting T2* effects in the myocardial perfusion arterial input function avoids overestimation of myocardial blood flow

Background Quantitative myocardial perfusion imaging requires correct measurement of arterial Gd concentration as the input function (AIF). An underestimation of AIF Gd concentration will lead to overestimation of myocardial blood flow (MBF). One source of this underestimation is the T2* effect due to high Gd concentration in the AIF measurement. Despite the short echo time (0.65 ms) used in th...

متن کامل

The role of relative cerebral blood volume obtained from Perfusion Weighted Imaging-MRI in glioma tumor grading before surgery

Introduction: Glioma is the most common type of brain malignancy among adults. Treatment for this type of tumor involves surgery, radiotherapy, and in higher grades, including chemotherapy. The precise grading of the tumor is critical for treatment planning and prognosis determining. Considering the possibility of problems such as errors in tissue sampling during surgery, as we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2001

ISSN: 0740-3194,1522-2594

DOI: 10.1002/1522-2594(200103)45:3<477::aid-mrm1063>3.0.co;2-4