Correction for Series Resistance in A.C. Polarography

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

a time-series analysis of the demand for life insurance in iran

با توجه به تجزیه و تحلیل داده ها ما دریافتیم که سطح درامد و تعداد نمایندگیها باتقاضای بیمه عمر رابطه مستقیم دارند و نرخ بهره و بار تکفل با تقاضای بیمه عمر رابطه عکس دارند

Polarography in Molten Salts

TYPES OF MELTS From the practical viewpoint, melts may be classified according to melting points which may limit the available techniques. The lowest melting, with working temperatures up to 250°, are typified by the LiNO3—NaNO3— KNO3 eutectic, NaNO3—KNO3 eutectic, LiClO4, and ammonium formate. With these solvents it is possible to use the dropping mercury electrode, or hanging mercury drop ele...

متن کامل

Software-based correction of single compartment series resistance errors.

Resistance across a patch pipette following seal formation and attainment of the whole cell recording configuration can introduce considerable and sometimes non-intuitive errors into voltage clamp recordings. These errors can be corrected actively on most commercially available amplifiers, although decisions during the experiment often must be made concerning the degree of correction to be empl...

متن کامل

Developments in Chromato-polarography

Developments in chromato-polarography and the results obtained from its application to the analysis of mixtures of organic compounds are presented. The possibility of determining traces of organic impurities in organic substances by this technique is evaluated. The polarographic method is today one of the most important instrumental methods and has found wide application in analytical chemistry...

متن کامل

Importance of Attenuation Correction (AC) for Small Animal PET Imaging.

UNLABELLED The purpose of this study was to investigate whether a correction for annihilation photon attenuation in small objects such as mice is necessary. The attenuation recovery for specific organs and subcutaneous tumors was investigated. A comparison between different attenuation correction methods was performed. METHODS Ten NMRI nude mice with subcutaneous implantation of human breast ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Review of Polarography

سال: 1971

ISSN: 0034-6691,1884-7692

DOI: 10.5189/revpolarography.17.21