Correction of partial volume effect in SPECT
نویسندگان
چکیده
منابع مشابه
Image-Based Partial-Volume Correction in SPECT
Introduction and aim: In SPECT imaging, the finite spatial resolution of the imaging system leads to a blurring of the reconstructed image. Consequently, counts originating from each point in the source distribution will be spread out over a volume in the reconstructed image, leading to spill-over of counts between different structures and distortion of the apparent activity concentration. This...
متن کاملImproved 3D correction for partial volume effects in brain SPECT.
An improved method for correction of partial volume effects (PVE) in brain SPECT is proposed. It is fully three-dimensional, does not require particular patient positioning, and works with scans only partially covering the brain. The location of functionally inactive brain regions (primarily cerebrospinal fluid) is extracted from high-resolution MRI. An automatic 3D registration algorithm then ...
متن کاملIntegrated software for the analysis of brain PET/SPECT studies with partial-volume-effect correction.
UNLABELLED We present software for integrated analysis of brain PET studies and coregistered segmented MRI that couples a module for automated placement of regions of interest (ROI) with 4 alternative methods for partial-volume-effect correction (PVEc). The accuracy and precision of these methods have been measured using 4 simulated (18)F-FDG PET studies with increasing degrees of atrophy. ME...
متن کاملApparent CBF decrease with normal aging due to partial volume effects: MR-based partial volume correction on CBF SPECT.
Several studies using single photon emission tomography (SPECT) have shown changes in cerebral blood flow (CBF) with age, which were associated with partial volume effects by some authors. Some studies have also demonstrated gender-related differences in CBF. The present study aimed to examine age and gender effects on CBF SPECT images obtained using the 99mTc-ethyl cysteinate dimer and a SPECT...
متن کاملCorrection for partial-volume effects on brain perfusion SPECT in healthy men.
UNLABELLED The limited spatial resolution of SPECT scanners does not allow an exact measurement of the local radiotracer concentration in brain tissue because partial-volume effects (PVEs) underestimate concentration in small structures of the brain. The aim of this study was to determine which brain structures show greater influence of PVEs in SPECT studies on healthy volunteers and to investi...