Correlation between GEM Premier 3000 and Vitros5.1+5600, SYSMEX XN-9000 in Detecting Electrolytes and Red Blood Cell Volume
نویسندگان
چکیده
Objective: To explore the consistency and relevance of results bedside rapid blood gas analyzer GEM premier 3000, Vitros5.1+5600 biochemical immunoassay SYSMEX XN-9000 automatic cell in central laboratory detecting serum potassium (K+), serumsodium (Na+), glucose (Glu), hemoglobin (Hb) red volume (Hct). And to provide a reference for accurate interpretation analysis report. Method: Usually, ICU patients will be taken arterial gas, samples through indwelling needle; at same time patients’ potassium, sodium, glucose, detected. This study implemented paired t-test correlation regression on each group data, used quality requirements (allowable total error) CLIA’88 proficiency testing program as criteria clinical acceptance. Results: The showed that sodium detected by 3000 were significantly different; different (P +, Na+, Glu, Hb Hct two sets instruments is less than allowable error CLIA’88, SE Na+ half CLIA’88. Conclusion: test have good correlation, but not good. cannot replace laboratory.
منابع مشابه
Assessment of blood sample stability for complete blood count using the Sysmex XN-9000 and Mindray BC-6800 analyzers
BACKGROUND Different hematological analyzers have different analytical performances that are often reflected in the criteria for sample stability of the complete blood count. This study aimed to assess the stability of several hematological parameters using the XN-9000 Sysmex and BC-6800 Mindray analyzers. METHODS The impact of storage at room temperature and 4°C was evaluated after 2, 4, 6, ...
متن کاملCorrelation between red blood cell transfusion volume and mortality in patients with massive blood transfusion: A large multicenter retrospective study
This study aimed to explore the correlation between red blood cell (RBC) transfusion volume and patient mortality in massive blood transfusion. A multicenter retrospective study was carried out on 1,601 surgical inpatients who received massive blood transfusion in 20 large comprehensive hospitals in China. According to RBC transfusion volume and duration, the patients were divided into groups a...
متن کاملPerformance of Gem Premier blood gas/electrolyte analyzer evaluated.
We evaluated a new analyzer designed for point-of-care testing of blood gases, sodium, potassium, ionized calcium, and hematocrit. The Gem Premier (Mallinckrodt) system has two components: the analyzer and a disposable cartridge. Analysis takes place in the cartridge, which contains the electrochemical sensors, the calibrants, the reagents, the sampling stylus, and the waste container. The syst...
متن کاملcohesion and cohesive devices in a contrastive analysis between ge and esp texts
the present study was an attempt to conduct a contrastive analysis between general english (ge) and english for specific purposes (esp) texts in terms of cohesion and cohesive devices. to this end, thirty texts from different esp and ge textbooks were randomly selected. then they were analyzed manually to find the frequency of cohesive devices. cohesive devices include reference, substitution, ...
15 صفحه اولEffect of adrenaline and blood gas conditions on red cell volume and intra-erythrocytic electrolytes in the carp, Cyprinus carpio.
1. Carp, when subjected to air stress in vivo, developed a hypoxaemia associated with an acidosis due to elevation of PCO2 and arterial lactate content. Adrenaline and noradrenaline levels rose markedly, and the mean corpuscular haemoglobin concentration (MCHC in mmol Hb l-1 red blood cells) decreased, indicating swelling of the erythrocytes. 2. No effect of adrenaline could be observed in vitr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Biomedical Science and Engineering
سال: 2022
ISSN: ['1937-688X', '1937-6871']
DOI: https://doi.org/10.4236/jbise.2022.151005