Correspondence on base isolated structures
نویسندگان
چکیده
منابع مشابه
Earthquake Analysis of Base Isolated Structures Including Soil-Structure Interaction
A frequency domain dynamic analysis is needed to obtain the response of structures constructed on a system of base isolators on flexible soil when subjected to earthquake ground motion. In such systems, the lateral stiffness of the base isolators is so small, compared to the structural stiffness, that in an earthquake attack the fundamental vibration mode dominates the response. With this in mi...
متن کاملEarthquake Analysis of Base Isolated Structures Including Soil-Structure Interaction
A frequency domain dynamic analysis is needed to obtain the response of structures constructed on a system of base isolators on flexible soil when subjected to earthquake ground motion. In such systems, the lateral stiffness of the base isolators is so small, compared to the structural stiffness, that in an earthquake attack the fundamental vibration mode dominates the response. With this in mi...
متن کاملearthquake analysis of base isolated structures including soil-structure interaction
a frequency domain dynamic analysis is needed to obtain the response of structures constructed on a system of base isolators on flexible soil when subjected to earthquake ground motion. in such systems, the lateral stiffness of the base isolators is so small, compared to the structural stiffness, that in an earthquake attack the fundamental vibration mode dominates the response. with this in mi...
متن کاملDEVELOPMENT OF RELATION FOR THE SEISMICALLY BASE ISOLATED STRUCTURES USING MODIFIED ABC ALGORITHM
In this paper, the effective parameters on the ductility demand of the seismically base isolated structure are investigated, and then a relation between the strength reduction factor and the target ductility is presented. The investigation has been conducted by modelling the base isolated structure as a two degree of freedom model in the OpenSees software, and the possibility of yielding in the...
متن کاملEvaluation of the SEAOC/UBC97 Provisions for the Tall Base-Isolated Structures
The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Bulletin of the New Zealand Society for Earthquake Engineering
سال: 1979
ISSN: 2324-1543,1174-9857
DOI: 10.5459/bnzsee.12.4.362-364