Grey Relational Analysis for Insulation Condition Assessment of Power Transformers Based Upon Conventional Dielectric Response Measurement

Conventional dielectric response measurement techniques, for instance, recovery voltage measurement (RVM), frequency domain spectroscopy (FDS) and polarization–depolarization current (PDC) are effective nondestructive insulation monitoring techniques for oil-impregnated power transformers. Previous studies have focused mainly on some single type of dielectric measurement method. However, the co...

متن کامل

Development of Condition Monitoring Instrumentation for Sensing Power Transformers

The objective of this work is the design and development of the Data Acquisition and Storage parts of a measurement system that will be used for the Condition Monitoring (CM) of Power Transformers. The data captured from the sensors and stored in a database will be used by an application that will predict the behavior of the Power Transformer. Data Store and Data Acquisition were developed usin...

متن کامل

Condition Monitoring Techniques of Power Transformers: A Review

Power transformers provide a vital link between the generation and distribution of produced energy. Such static equipment is subjected to abuse during operation in generation and distribution stations and leads to catastrophic failures. This paper reviewed the techniques in the field of condition monitoring of power transformers in recent years. Transformer monitoring and diagnosis are the effe...

متن کامل

Ferroresonance Phenomenon in Power Transformers - Experimental Assessment

This paper reports on the results of recent research and development efforts to study and assess various impacts of ferroresonance phenomenon on operating performance of power transformers and to investigate ways to mitigate the effects of such phenomenon. Three-phase core-type transformers are used in the study. The results of the technical investigation and the associated ferroresonance exper...

متن کامل

Condition and risk assessment of power transformers: a general approach to calculate a Health Index

Power transformers are the most important assets in substations and play an important role in the reliability of electrical systems and in the quality of the energy delivered. As the population of transformers in service is getting old, much attention must be focused on transformers availability and reliability. So the condition and risk assessment of the transformers are more and more importan...