Cost-Effective Placement of Phasor Measurement Units to Defend against False Data Injection Attacks on Power Grid
نویسندگان
چکیده
منابع مشابه
Power system observability with minimum phasor measurement units placement
This paper presents optimal phasor measurement units (PMUs) placement algorithms for power system observability. The optimal placement problem (OPP) is formulated such that minimizing the number of PMU installations for full network observability. Three approaches, in this paper, are introduced aiming at reducing the computational burden in Optimal Placement problems. Depth First Search, Simula...
متن کاملPresenting a New Method Based on Branch Placement for Optimal Placement of Phasor Measurement Units
In this paper, a new method based on branch placement for the optimal positioning of Phasor Measurement Units (PMUs) in power systems is proposed. In this method, the PMUs are in type of single-channel and are installed at the beginning of the branches. Therefore, they are able to measure the bus voltages. Also, the installation of the PMUs on the branches increases the security of observabilit...
متن کاملResilient Configuration of Distribution System versus False Data Injection Attacks Against State Estimation
State estimation is used in power systems to estimate grid variables based on meter measurements. Unfortunately, power grids are vulnerable to cyber-attacks. Reducing cyber-attacks against state estimation is necessary to ensure power system safe and reliable operation. False data injection (FDI) is a type of cyber-attack that tampers with measurements. This paper proposes network reconfigurati...
متن کاملFalse Data Injection Attacks in Smart Grid: Challenges and Solutions
Smart Grid, as an energy-based Cyber-Physical Sys tem (CPS), is a new type of power grid that will provide reliable, secure, and efficient energy transmission and distribution. As the quality of assurance of monitoring data is essential to smart grid, in this talk we will first present two dangerous false data injection attacks, which target the state estimation and energy distribution in smar...
متن کاملOptimal Placement of Phasor Measurement Units Using Gravitational Search Method
This paper presents a methodology using Gravitational Search Algorithm for optimal placement of Phasor Measurement Units (PMUs) in order to achieve complete observability of the power system. The objective of proposed algorithm is to minimize the total number of PMUs at the power system buses, which in turn minimize installation cost of the PMUs. In this algorithm, the searcher agents are colle...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2020
ISSN: 1996-1073
DOI: 10.3390/en13153862