Cranial bone reconstruction with customized implants after trauma
نویسندگان
چکیده
منابع مشابه
Reconstruction of cranial bone defects using alloplastic implants produced from a stereolithographically-generated cranial model.
Larger cranial bone defects can cause cranial disfigurement as well as potential mechanical brain trauma. Conventionally pre-fabricated acrylic cranioplasty implants require complicated procedures and result in potential dimensional and contour inaccuracies. The development of stereolithographic techniques for generating acrylic resin skull models allows the pre-fabrication of custom acrylic re...
متن کاملReconstruction of Cranial Bone Defects with Fiber-reinforced Composite–bioactive Glass Implants
Jaakko Piitulainen Reconstruction of cranial bone defects with fiber-reinforced composite–bioactive glass implants From the University of Turku, Faculty of Medicine, Department of Otorhinolaryngology–Head and Neck Surgery and the Department of Biomaterials Science, Doctoral Programme of Clinical Investigation; and Turku University Hospital, Turku, Finland Annales Universitas Turkuensis Ser. D, ...
متن کاملComparing 3-Dimensional Virtual Reconstruction methods in Customized Implants
In medical and surgery applications, the implant design is the key. Any mismatch in the implant design results in the implant failure as well as psychological stress and pain to the patient. Measuring and inspecting the geometrical implant design with the reference model is very important, to ensure the proper fitting and safety of the patient. The purpose of this study is to perform the evalua...
متن کاملReconstruction of cranial bone defects with BMP-2 releasing scaffolds
Kyung Shin Kang, Jin Woo Lee, Ki-Joo Kim, Jong-Won Rhie, and Dong-Woo Cho 4 Department of Mechanical Engineering, POSTECH, Pohang, Gyungbuk, 790-784, Korea Department of Nano Engineering, University of California, San Diego, CA, USA Department of Plastic Surgery, College of medicine, The Catholic University of Korea, Seoul, Korea Division of Integrative Biosciences and Biotechnology, POSTECH, P...
متن کاملBone density study of the proximal femur after hip arthroplasty with porous-coated implants
Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Cirugía y Cirujanos (English Edition)
سال: 2019
ISSN: 2444-0507
DOI: 10.24875/cirue.m18000043