CRT-700.59 Radiation Dose Reduction in Structural Heart Disease Interventions Using Noise Reduction Technology
نویسندگان
چکیده
منابع مشابه
Radiation Dose Reduction Techniques in the Workplace
The principal objective of radiation protection is to ensure that the dose received by any individual does not exceed the applicable M.P.D. values.We will discuss in this paper the presents recommendations and technical information related to the design and installation of structural shielding with taking into account the concept of Maximum Permissible Dose equivalent (MPDl as expressed and ...
متن کاملReducing Radiation Dose in Coronary Angiography and Angioplasty Using Image Noise Reduction Technology.
This study sought to quantitatively evaluate the reduction of radiation dose in coronary angiography and angioplasty with the use of image noise reduction technology in a routine clinical setting. Radiation dose data from consecutive 605 coronary procedures (397 consecutive coronary angiograms and 208 consecutive coronary interventions) performed from October 2014 to April 2015 on a coronary an...
متن کاملSubstantial radiation reduction in pediatric and adult congenital heart disease interventions with a novel X-ray imaging technology
BACKGROUND Pediatric catheterization exposes patients to varying radiation doses. Concerns over the effects of X-ray radiation dose on the patient population have increased in recent years. This study aims at quantifying the patient radiation dose reduction after the introduction of an X-ray imaging technology using advanced real time image noise reduction algorithms and optimized acquisition c...
متن کاملSiemens angiography and MediGuideTM Technology facilitate significant dose reduction during Cardiac Resynchronization Therapy (CRT)
The study showed reductions fluoroscopy time and radiation exposure of up to 90% when compared to conventional (exclusively fluoroscopy-guided) CRT implantations. There were no negative consequences on procedural efficacy and no complications. Background CRT and MediGuideTM Technology CRT is a well established therapy for patients with advanced Heart Failure (HF). The number of implantations is...
متن کاملThe Effectiveness of Noise Reduction Interventions in Neonatal Intensive Care Units: A review Article
Background: High noises in the NICU are known to have negative effects on the health and wellness of hospitalized preterm infants. Various technologies for the care of preterm infants, extensive therapeutic interventions and communication between staff are among the causes of loud noise in these wards. The aim of this review article is to evaluate the effectiveness of noise reduction intervent...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JACC: Cardiovascular Interventions
سال: 2018
ISSN: 1936-8798
DOI: 10.1016/j.jcin.2018.01.215