Cryogen-free heterodyne-enhanced mid-infrared Faraday rotation spectrometer
نویسندگان
چکیده
منابع مشابه
Broadly tunable mid-infrared noise-immune cavity-enhanced optical heterodyne molecular spectrometer.
The sensitive spectroscopic technique noise-immune cavity-enhanced optical heterodyne molecular spectroscopy (NICE-OHMS) has been successfully used in a variety of systems; however, no broadly tunable setup has been developed for the mid-infrared. To this end, we have integrated a difference frequency generation system into a NICE-OHMS setup. Initial optimization and characterization was comple...
متن کاملFabry-Perot enhanced Faraday rotation in graphene.
We demonstrate that giant Faraday rotation in graphene in the terahertz range due to the cyclotron resonance is further increased by constructive Fabry-Perot interference in the supporting substrate. Simultaneously, an enhanced total transmission is achieved, making this effect doubly advantageous for graphene-based magneto-optical applications. As an example, we present far-infrared spectra of...
متن کاملEnhanced small-scale Faraday rotation in the Galactic spiral arms
We present an analysis of the rotation measures (RMs) of polarized extragalactic point sources in the Southern Galactic Plane Survey. This work demonstrates that the statistics of fluctuations in RM differ for the spiral arms and the interarm regions. Structure functions of RM are flat in the spiral arms, while they increase in the interarms. This indicates that there are no correlated RM fluct...
متن کاملMid-infrared spectrometer using opto-nanofluidic slot-waveguide for label-free on-chip chemical sensing.
A mid-infrared (mid-IR) spectrometer for label-free on-chip chemical sensing was developed using an engineered nanofluidic channel consisting of a Si-liquid-Si slot-structure. Utilizing the large refractive index contrast (Δn ∼ 2) between the liquid core of the waveguide and the Si cladding, a broadband mid-IR lightwave can be efficiently guided and confined within a nanofluidic capillary (≤100...
متن کاملFaraday rotation measurements on compact helical system by using a phase sensitive heterodyne polarimeter
A phase sensitive heterodyne polarimeter was installed on compact helical system ~CHS!. An HCN laser ~337 mm! and Schottky barrier diodes are used for the radiation source and for detection, respectively. By using a phase sensitive heterodyne scheme, the Faraday rotation angle can be measured from the phase variations caused by the phase difference between the rightand left-handed waves in the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2013
ISSN: 1094-4087
DOI: 10.1364/oe.21.000740