Cryogenic UHV Specimen Preparation for APT: A Transfer Solution
نویسندگان
چکیده
منابع مشابه
Specimen Preparation for Electron Microscopy
In general the SEM sample preparation techniques are more or less similar to the metallographic sample preparation technique for optical microscopy, because both the microscopes reveals the surface topography of sample. In SEM a focussed beam of electrons scans over the specimen surface and the electrons emitted from the sample surface controls the brightness of the CRT spot which also scans th...
متن کاملCryogenic Fluid Transfer for Exploration
This paper discusses current plans and issues for exploration that involve the use of cryogenic transfer. The benefits of cryogenic transfer to exploration missions are examined. The current state of the art of transfer technology is reviewed. Mission concepts of operation for exploration are presented, and used to qualitatively discuss the performance benefits of transfer. The paper looks at t...
متن کاملTEM specimen preparation techniques
Transmission electron microscopy (TEM) is a powerful tool for the investigation of the microstructure of materials, providing crystallographic information and composition at the nanometer scale. For such studies, samples should be transparent to the electron beam. In this review, TEM sample preparation techniques for different classes of materials, such as metals and alloys, multilayered coatin...
متن کاملControlled environment specimen transfer.
Specimen transfer under controlled environment conditions, such as temperature, pressure, and gas composition, is necessary to conduct successive complementary in situ characterization of materials sensitive to ambient conditions. The in situ transfer concept is introduced by linking an environmental transmission electron microscope to an in situ X-ray diffractometer through a dedicated transmi...
متن کاملAdvanced Techniques in TEM Specimen Preparation
The recent development of Dual-BeamTM or Cross-BeamTM FIB systems has gradually taken over the traditional single beam FIB systems. A typical FIB column contains a liquid metal ion source that produces a finely focused Ga ion beam. The primary Ga ion beam is accelerated by 30-50 kV, and directed towards the features of interest on the specimen. The incident ion beam will sputter atoms from the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2019
ISSN: 1431-9276,1435-8115
DOI: 10.1017/s1431927619003374