Cryptosporidium antigen detection in human feces by reverse passive hemagglutination assay

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cryptosporidium antigen detection in human feces by reverse passive hemagglutination assay.

A reverse passive hemagglutination (RPH) assay was developed for Cryptosporidium oocyst antigen with an antioocyst monoclonal antibody (MAb; MAb-C1) coupled to stabilized sheep erythrocytes. RPH was compared with microscopy of auramine-phenol-stained smears of 56 oocyst-positive fecal samples, each of which was tested blindly by RPH with two oocyst-negative samples received on the same day (a t...

متن کامل

Detection of rotavirus antibody by inhibition of reverse passive hemagglutination.

A reverse passive hemagglutination inhibition (RPHI) test was developed for detecting rotavirus antibody in patients' sera. Sheep erythrocytes coated with guinea pig antibody against Nebraska calf diarrhea virus (NCDV) were readily hemagglutinated by NCDV in a reaction called reverse passive hemagglutination (RPHA). Inhibition of this RPHA reaction was used to detect the presence of rotavirus a...

متن کامل

Rapid Detection of Human Group C Rotaviruses by Reverse Passive Hemagglutination and Latex Agglutination Tests

Reverse passive hemagglutination (RPHA) tests and a latex agglutination test with monoclonal antibodies (MAbs) were developed for the rapid detection of noncultivatable human group C rotaviruses. For RPHA tests, two MAbs, MAb 5A12 recognizing the outer capsid and MAb 13A3 recognizing the inner capsid, were separately used for the coating of sheep erythrocytes (SRBCs). Forty-six fecal samples we...

متن کامل

Neutralization assay for human group C rotaviruses using a reverse passive hemagglutination test for endpoint determination.

A novel neutralization assay for human group C rotavirus (CHRV) was developed by using a reverse passive hemagglutination (RPHA) test for endpoint determination. In this assay, the neutralization (N)-RPHA test, serial twofold dilutions of sera were mixed with a solution of CHRV that yielded an RPHA test titer of 8 at 3 days after infection. The mixtures were incubated at 37 degrees C for 1 h an...

متن کامل

Detection of Cryptosporidium parvum oocysts in bovine feces by monoclonal antibody capture enzyme-linked immunosorbent assay.

A monoclonal antibody enzyme-linked immunosorbent assay (ELISA) was developed to detect Cryptosporidium parvum oocysts in bovine feces. Fecal oocysts were concentrated by centrifugation through Formalin-ethyl acetate solution and captured with monoclonal antibody 18.280.2 reactive with C. parvum oocysts. Captured oocysts were detected with goat anti-oocyst serum, following the addition of a per...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical Microbiology

سال: 1994

ISSN: 0095-1137,1098-660X

DOI: 10.1128/jcm.32.11.2755-2759.1994