Cuff inflator for tracheal tubes

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic endotracheal tube cuff inflator and continuous pressure monitor/controller.

Endotracheal tube cuff pressure over 30 cm of water has been found to occur in about 50% of cases where cuff inflation was performed without monitoring, using pilot balloon palpation, minimal leak, or minimal occlusive volume techniques1. The incidence of post operative respiratory complications such as cough, sore throat, hoarseness, blood-streaked expectoration, and even tracheal stenosis is ...

متن کامل

Laboratory evaluation of 4 brands of endotracheal tube cuff inflator.

INTRODUCTION Routine measurement of endotracheal tube (ETT) cuff pressure is a standard in respiratory care, and several devices are available for measuring ETT cuff pressure. Yet an informed choice in the buying process is hindered by the present paucity of unbiased, comparative data. METHODS Four brands of cuff inflator were tested: Posey Cufflator, DHD Cuff-Mate 2, Rüsch Endotest, and SIMS...

متن کامل

Rapid pressure compensation by automated cuff pressure controllers worsens sealing in tracheal tubes.

BACKGROUND Cyclic redistribution of air within the cuff during respiratory pressure changes creates a self-sealing mechanism which allows tracheal sealing, despite tracheal airway pressure being above baseline cuff inflation pressure. The aim of the present study was to investigate the effect of continuous automated cuff pressure regulation on tracheal sealing during cyclic respiratory pressure...

متن کامل

Direct measurement of mucosal pressures exerted by cuff and non-cuff portions of tracheal tubes with different cuff volumes and head and neck positions.

We measured directly mucosal pressures against the cuff and non-cuff portions of the tracheal tube in different head-neck positions and tested the reliability of calculated mucosal pressures, in vivo intracuff pressures and cuff volume as determinants of directly measured mucosal pressures. We studied 10 anaesthetized, paralysed adult patients. An 8.5-mm, high volume, low pressure PVC tracheal ...

متن کامل

Tracheal stricture secondary to cuffed tracheostomy tubes.

1 Blumenthal MR and Kornfeld P: Edrophonium chloride for paroxysmal auricular tachycardia. JAMA 161:1001, 1956 2 Moss AJ and Aledort LM: Use of edrophonium (Tensilo&) in the evaluation of supravenhicular tachycardias. Amer J Cardiol, 17:58,1966 3 Bellet S: Clinical Disorders of the Heart Beat (2nd Ed). Philadelphia, Lea & Febiger, 1963, p 998 4 Gould L and Lyon AL: Conversion of atrial flutter ...