Cutaneous-Pericardial Fistula: Rare Complication of Transapical Aortic Valve Replacement—Case Report and Literature Review
نویسندگان
چکیده
منابع مشابه
Cutaneo-pericardial fistula after transapical aortic valve implantation.
Transcatheter aortic valve implantation (TAVI) represents a therapeutic option of increasing impact for the treatment of high-risk patients with symptomatic, severe aortic valve stenosis. We report here the case of an 86-year old patient with a cutaneo-pericardial fistula after a transapical TAVI procedure.
متن کاملMycotic aortic aneurysm as a postsurgical complication: report of a case and review of the literature
Mycotic aneurysms are localized and irreversible dilatations of the arteries caused by weakening and damaging the arterial wall by an invasive organism establishing infective arteritis. Mycotic aneurysm of the thoracic aorta is a rare event; however, it can be fatal if not diagnosed early or not treated appropriately. Clinical findings are usually nonspecific; however, c...
متن کاملA rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure
Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...
متن کاملCutaneo-Pericardial Fistula After Transapical Approach for Transcatheter Aortic Valve Replacement.
A 77-year-old male with severe aortic stenosis, prior coronary artery bypass graft, recurrent infective endocarditis, and chronic Q fever (taking hydroxychloroquine and doxycycline) underwent a transcatheter aortic valve replacement (TAVR) by the transapical (TA) approach via left thoracotomy. A 29-mm Edwards SAPIEN XT valve (Edwards Lifesciences, Irvine, California) was successfully deployed u...
متن کاملRare complication of bioprosthetic aortic valve replacement.
CE-Perimount aortic bioprosthesis in a 59-year-old-man, implanted 8 years ago, showed non-infective severe structural deterioration. Preoperative echocardiogram demonstrated a prolapsing cusp (Fig. 1(A—C)); however, intra-operative echocardiogram and findings revealed a ‘missing’ leaflet (Figs. 1(D), 2(A and B) and Video 1). www.elsevier.com/locate/ejcts European Journal of Cardio-thoracic Surg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Case Reports in Surgery
سال: 2020
ISSN: 2090-6900,2090-6919
DOI: 10.1155/2020/2371423