Cyclic Behavior of Bolted Extended End-Plate Moment Connections with Different Sizes of End Plate and Bolt Stiffened by a Rib Plate
نویسندگان
چکیده
منابع مشابه
Experimental Study and Comparative Numerical Analysis of the Mechanical Behavior of Extended End-Plate Connections with End-Plate Stiffeners
To investigate the influence of end-plate stiffeners on the initial rotational stiffness of extended end-plate internal joints, an experimental program was carried out to investigate the rotational behavior of the joints. Two finite element methods (FEMs) were proposed using ABAQUS software. The stress distribution, plastic development, and deformation characteristics of extended end-plate join...
متن کاملNumerical Analysis of End Plate Bolted Connection with Corrugated Beam
Steel extended end plate bolted connections are recommended to be widely utilized in special moment-resisting frame subjected to monotonic loading. Improper design of steel beam to column connection can lead to the collapse and fatality of structures. Therefore comprehensive research studies of beam to column connection design should be carried out. Also the performance and effect of corrugated...
متن کاملSubstructure of Amphibian Motor End Plate
End-plate membrane has been examined at amphibian myoneural junctions by means of transmission electron microscopy of thin tissue sections. The postjunctional membrane exhibits morphologically specialized dense, convex patches which are located superficially facing the axon terminal but do not extend into the depths of the junctional folds. In the specialized regions the plasma membrane is appr...
متن کاملThermodynamic Parameters of End-plate Channel Blockade1
The reaction kinetics for drug blockade of postsynaptic channels at the mouse neuromuscular junction were studied. The activation energies associated with the onward and off-rate constants, from a sequential model, were measured for procaine, scopolamine, octanol, and heptanol, and from these the transition state thermodynamic parameters of free energy (AG$), enthalpy (AHI), and entropy (ASS) o...
متن کاملActive phase of frog's end-plate potential.
IT HAS BEEN CONSIDERED that the end-plate potential (e.p.p.) is generated by the brief ionic flux across the end-plate membrane and the later slowly declining phase of the e.p.p. is due to the dissipation of the charge along and across the muscle membrane. This consideration was supported by some authors. Kuffler (21) observed with a single nerve-muscle preparation that the later slowly decayin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Civil Engineering Journal
سال: 2018
ISSN: 2476-3055
DOI: 10.28991/cej-030979