CYCLIC LOADING EXPERIMENT ON LEAD RUBBER BEARING WITH LARGE DIAMETER LEAD PLUG

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the effect of characteristic strength on seismic beharior with lead rubber bearing

conventional methods for seismic design of structures are based on building capacity. because of the disadvantages of conventional methods, base isolation system  is known as an effective solution to protect structures against earthquakes. in this study the operation of 2-storey steel frame with and without seismic isolators under near-fault earthquake of chichi، northridge and  capemendocine  ...

متن کامل

Adaptive fuzzy control for earthquake-excited buildings with lead rubber bearing isolation

This study examines the feasibility of applying adaptive fuzzy sliding mode control (AFSMC) strategies to reduce the dynamic responses of buildings constructed using a lead rubber bearing (LRB) isolation hybrid protective system. Recently developed control devices for civil engineering structures, including hybrid systems and semi-active systems, have been found to have inherent nonlinear prope...

متن کامل

Adaptive Fuzzy Sliding Mode Control for Seismically excited Bridges with lead Rubber Bearing Isolation

This study examines the feasibility of applying adaptive fuzzy sliding mode control (AFSMC) strategies to reduce the dynamic responses of bridges constructed using a lead rubber bearing (LRB) isolation hybrid protective system. Recently developed control devices for civil engineering structures, including hybrid systems and semi-active systems, have been found to have inherent nonlinear propert...

متن کامل

Implantable cardioverter-defibrillator lead failure in children and young adults: a matter of lead diameter or lead design?

OBJECTIVES This study aimed to investigate the impact of lead diameter and design on implantable cardioverter-defibrillator (ICD) lead survival in children and young adults. BACKGROUND Recent reports have called attention to high rates of lead failure in adults with small-diameter ICD leads, but data in the pediatric population is limited. METHODS We reviewed lead performance in consecutive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: AIJ Journal of Technology and Design

سال: 2016

ISSN: 1341-9463,1881-8188

DOI: 10.3130/aijt.22.987