Dark Signal Temperature Dependence Correction Method for Miniature Spectrometer Modules
نویسندگان
چکیده
منابع مشابه
Miniature Neutron-Alpha Activation Spectrometer
We are developing a miniature neutron-alpha activation spectrometer for in-situ analysis of chem-bio samples, including rocks, fines, ices, and drill cores, suitable for a lander or Rover platform for Mars or outer-planet missions. In the neutron-activation mode, penetrating analysis will be performed of the whole sample using a y spectrometer and in the ex-activation mode, the sample surface w...
متن کاملTemperature Dependence of GaNHEMT Small Signal Parameters
This study presents the temperature dependence of small signal parameters of GaN/SiC HEMTs across the 0–150◦C range. The changes with temperature for transconductance (gm), output impedance (Cds and Rds), feedback capacitance (Cdg), input capacitance (Cgs), and gate resistance (Rg) are measured. The variations with temperature are established for gm, Cds, Rds, Cdg, Cgs, and Rg in the GaN techno...
متن کاملMiniature, sub-nanometer resolution Talbot spectrometer.
Miniaturization of optical spectrometers has a significant practical value as it can enable compact, affordable spectroscopic systems for chemical and biological sensing applications. For many applications, the spectrometer must gather light from sources that span a wide range of emission angles and wavelengths. Here, we report a lens-free spectrometer that is simultaneously compact (<0.6 cm<s...
متن کاملA miniature mass spectrometer for chemical and biological sensing
An experimental study has been carried out using a Miniature Quadrupole Mass Spectrometer (MicroQuad) for gas analysis. Conventional quadrupole rods have been replaced with a micromachined mass filter made from silicon with Au metallised specially drawn glass fibres of length 30 mm and diameter 0.5 mm. A standard hot filament ion source and both Faraday detection and a channel electron multipli...
متن کاملTemperature dependence of dark current in a CCD
We present data for dark current of a back-illuminated CCD over the temperature range of 222 to 291 K. Using an Arrhenius law, we found that the analysis of the data leads to the relation between the prefactor and the apparent activation energy as described by the Meyer-Neldel rule. However, a more detailed analysis shows that the activation energy for the dark current changes in the temperatur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Sensors
سال: 2011
ISSN: 1687-725X,1687-7268
DOI: 10.1155/2011/608157