Dataset from the dynamic shake-table test of a full-scale unreinforced clay-masonry building with flexible timber diaphragms

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Testing unreinforced masonry structures at reduced scale

When testing multi-story structures on a shaking table, most testing facilities require a reduced scale model. Producing scale test units at small scale is particularly challenging for unreinforced masonry structures. Previous work by other researchers showed that scaling of units and mortar joints is mandatory in order to obtain for the reduced scale masonry failure modes, which are similar to...

متن کامل

Dynamic testing of a four-storey building with reinforced concrete and unreinforced masonry walls: prediction, test results and data set

This paper presents the results of a series of shake-table tests on a half-scale, four-storey building with reinforced concrete and unreinforced masonry walls. Due to the lack of reference tests, the seismic behaviour of such mixed structures is poorly understood. The test unit was subjected to several runs of increasing intensity yielding performance states between minor damage and near collap...

متن کامل

Scaling unreinforced masonry for reduced-scale seismic testing

When testing multi-storey structures, most testing facilities require the testing of a reduced-scale model. A literature review on tests of scaled masonry structural components revealed that scaling of masonry was rather challenging and often significant differences in stiffness, strength and failure mechanisms between the different sized masonry were reported. This paper addresses the scaling ...

متن کامل

Damage Identification Study of a Seven- Story Full-scale Building Slice Tested on the Ucsd-nees Shake Table

A full-scale seven-story reinforced concrete building section was tested on the UCSDNEES shake table during the period October 2005 January 2006. The shake table tests were designed to damage the building progressively through four historical earthquake records. At various levels of damage, ambient vibration tests and low amplitude white noise base excitations with root-mean-square acceleration...

متن کامل

Flexural Tension in Unreinforced Masonry

Unreinforced masonry is that in which the tensile strength of the masonry is taken into consideration in design. Allowable out-of-plane tensile stress values are a function of the mortar type, such as Portland cement/lime mortar vs. masonry cement mortar or type M or S mortar vs. type N mortar. The allowable tensile stress is also a function of the masonry construction, such as tension parallel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Data in Brief

سال: 2018

ISSN: 2352-3409

DOI: 10.1016/j.dib.2018.03.047