Dead-time Compensation Strategy of Three Level Inverter Based on FFT
نویسندگان
چکیده
منابع مشابه
Repetitive Control Based Pwm Inverter Dead-time Compensation for Ac Servo Drive
AC servomotor speed or current controller based on PI control and/or optimal control, can not eliminate the cyclical fluctuations of speed or current when subject to periodic disturbances. However, repetitive control performs well when the disturbance is cyclical with constant period (frequency). For a PWM (Pulse Width Modulated) inverter driven AC servomotor, a time delay is inserted between t...
متن کاملFault Strategy Analysis for Three - phase Cascaded Multi - level Inverter
This study includes a multilevel cascaded inverter along with a control strategy. This proposed control scheme directs the inverter to support the grid under three phase balanced voltage sags and during one or two phase faults. Control of voltage between grid and Distributed Generation (DG) system is a challenging subject. Integrating DG with the grid is the fundamental element of this study wh...
متن کاملThree-level NPC inverter based new DSTATCOM topologies and their performance evaluation for load compensation
Now-a-days for effective load compensation, a conventional three-level neutral point clamped (CNPC) inverter topology is more preferably used. This compensator, however, faces the problems of additional clamping diodes, which reduces the redundant switching states and improves the problem of capacitor voltage imbalance; further increasing the inverter cost. In this paper, a detailed analysis of...
متن کاملA New Dead Time Compensation method for Stand - alone Inverter under Unbalanced Loads
phase stand-alone inverter is caused by unbalanced load and a dead time distorts inverter output voltage more unsymmetrically. When the inverter supplies unbalanced load, three phase output voltages include unbalanced odd harmonics but dq-axis voltages at synchronous reference frame have even harmonics with different magnitude each other. In this paper, a new compensation method is proposed to ...
متن کاملCPLD-Based Circuit Design of IGBT Dead-Time Compensation
IGBT (insulated-gate bipolar transistors) deadtime compensation circuit has a very important significant for improving the output voltage waveform of the inverter, reducing the harmonic output current. Thus, many compensation strategies are reported in literatures and have been implemented in industrial drives recently. Overall, the method of dead-time compensation can be divided into hardware ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: DEStech Transactions on Engineering and Technology Research
سال: 2019
ISSN: 2475-885X