Deep correction of breathing-related artifacts in real-time MR-thermometry
نویسندگان
چکیده
منابع مشابه
Inter-frame Motion Correction for MR Thermometry
Noninvasive temperature measurement is feasible with MRI to monitor changes in thermal therapy. Phase shift based MR thermometry gives an estimate of the relative temperature variation between thermal and baseline images. This technique is limited, however, when applied on targets under inter-frame motion. Simple image registration and subtraction are not adequate to recover the temperature pro...
متن کاملHybrid US/MR System for Real-Time Compensation of Breathing Motion Artifacts in Cardiovascular MRI at 3 Tesla
D. Giese, A. Bongers, J. Jenne, M. Günther, B. Jung, D. Foell, M. Zaitsev, J. Hennig, W. de Boer, and M. Markl Dept. of Diagnostic Radiology, Medical Physics, University Hospital Freiburg, Freiburg, Germany, mediri GmbH, Heidelberg, Germany, Cardiology and Angiology, University Hospital Freiburg, Freiburg, Germany, Institut für Experimentelle Kernphysik, Universität Karlsruhe (TH), Karlsruhe, G...
متن کاملReal-time MR artifacts filtering during continuous EEG/fMRI acquisition.
The purpose of this study was the development of a real-time filtering procedure of MRI artifacts in order to monitor the EEG activity during continuous EEG/fMRI acquisition. The development of a combined EEG and fMRI technique has increased in the past few years. Preliminary "spike-triggered" applications have been possible because in this method, EEG knowledge was only necessary to identify a...
متن کاملThe importance of phase drift correction for accurate MR thermometry in long duration MR-HIFU exposures
Background/introduction In MRI-guided high-intensity focused ultrasound (MRHIFU) therapy, temperature-dependent proton resonance frequency (PRF) shift is a key factor to quantify and visualize the spatial heating pattern in treated and surrounding tissue. However, during treatment, multiple scanner-related changes can impact the accuracy of the temperature measurements obtained with the PRF shi...
متن کاملReal Time Measurement of Heating Near Metallic Implants Throughout a Phantom Using Phase-Shift MR Thermometry
H. Bassen, A. Kam, W. Kainz, G. Mendoza, H. Wang Center for Devices and Radiological Health, Food and Drug Administration, Rockville, MD, United States, Diagnostic Radiology Department, National Institutes of Health, Bethesda, MD, United States Introduction – Potentially dangerous heating occurs at the narrow tip of certain medical implants in patients being imaged by standard MRI systems [1, 2...