Defibrillation Threshold Testing in Implantable Cardioverter-Defibrillators

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Defibrillation thresholds testing of implantable cardioverter-defibrillators at implantation.

I read with interest the reports on defibrillation testing (DFT) during implantable cardioverter-defibrillator (ICD) implantation published recently in JACC (1,2). There is a significant, albeit low, risk to serious complications including death during DFT testing. If the implantation data as measured through the device are satisfactory, then should we induce ventricular fibrillation (VF) in a ...

متن کامل

Defibrillation Threshold for Implantable Defibrillators

Background The time constant of truncated exponential pulses used with implantable defibrillators is determined by the output capacitor size and defibrillation pathway resistance. The optimal capacitor size is unknown. Methods and Results This study compared defibrillation threshold (DFT) for standard 120-,uF capacitors (DFT120) and smaller 60-,gF capacitors (DFT60) at implantation of cardiover...

متن کامل

Subcutaneous Implantable Cardioverter Defibrillators Implantation Without Defibrillation Threshold Testing: A Single Center Experience

Background Subcutaneous implantable cardioverter defibrillator (S-ICD) system has been proven to be an effective therapy for prevention of sudden cardiac death (SCD) in selected patients. Although the Shockless IMPLant Evaluation (SIMPLE) trial has shown that defibrillation threshold (DFT) testing is not necessary for transvenous ICD (TV-ICD) systems, it is still recommended for S-ICD systems. ...

متن کامل

Implantable cardioverter defibrillator with and without defibrillation threshold testing.

BACKGROUND Defibrillation threshold (DFT) testing at the time of implantable cardioverter defibrillator (ICD) insertion is performed routinely. This practice is being reconsidered due to doubts about its ability to improve ICD efficacy and evidence that survival may not be affected by the test. OBJECTIVES To compare the outcome of ICD recipients who underwent DFT testing and those who did not...

متن کامل