Deformable Slice-to-Volume Registration for Motion Correction of Fetal Body and Placenta MRI
نویسندگان
چکیده
منابع مشابه
Tractography in the fetal brain with correction of fetal and maternal motion using model-based slice to volume registration
Introduction Diffusion tensor imaging (DTI) of the fetal brain is attracting increasing interest [1-3] with recent papers starting to present tractography results [4]. To overcome maternal motion, many studies have been performed using breath-hold methods, although this severely reduces the amount of available data. However, even in breath-held acquisitions, the fetus can move substantially, so...
متن کاملCorrection of misaligned slices in multi-slice cardiovascular magnetic resonance using slice-to-volume registration
A popular technique to reduce respiratory motion for cardiovascular magnetic resonance is to perform a multi-slice acquisition in which a patient holds their breath multiple times during the scan. The feasibility of rigid slice-to-volume registration to correct for misalignments of slice stacks in such images due to differing breath-hold positions is explored. Experimental results indicate that...
متن کاملMRI-Guided Prostate Motion Tracking using Multislice-to-Volume Registration
MRI-guided prostate needle biopsy requires compensation for organ motion between target planning and needle placement. Two questions are studied and answered in this work: is rigid registration sufficient in tracking the targets with a maximum error of 3 mm (smaller than average prostate tumor size) and how many intra-operative slices are required to obtain this accuracy? We developed rigid and...
متن کاملPrenatal MRI visualisation of the aortic arch and fetal vasculature using motion-corrected slice-to-volume reconstruction
Methods Using overlapping multi-slice 2D single-shot fast spin echo sequences (Philips, 1.5T, TR = 15000 ms, TE = 100 ms, flip angle = 90 degrees, voxel size = 350 × 350 mm, slice thickness = 2.5 mm, SENSE factor = 2, partial Fourier-factor 5/8, slice duration 468 ms) in a fetus at 36 weeks gestation, we applied a novel GPU accelerated super-resolution algorithm for slice-volume registration to...
متن کاملConcurrent Geometric Distortion Correction in Mapping Slice-to-volume (MSV) Motion Correction of fMRI Time Series
D. Yeo, J. A. Fessler, B. Kim Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, MI, United States, Radiology, University of Michigan Medical School, Ann Arbor, MI, United States Introduction: The accuracy of measuring voxel intensity changes between stimulus and rest images in fMRI echo-planar imaging (EPI) data, from which brain activation maps are computed, is se...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Medical Imaging
سال: 2020
ISSN: 0278-0062,1558-254X
DOI: 10.1109/tmi.2020.2974844