Demonstrating a single-block 3D-segmented plastic-scintillator detector

نویسندگان

چکیده

Three-dimensional finely grained plastic scintillator detectors bring many advantages in particle detectors, allowing a massive active target which enables high-precision tracking of interaction products, excellent calorimetry and sub-nanosecond time resolution. Whilst such can be scaled up to several-tonnes, as required by future neutrino experiments, relatively long production time, where each single plastic-scintillator element is independently manufactured machined, together with potential challenges the assembly, complicates their realisation. In this manuscript we propose novel design for 3D granular O($1~\text{cm}^3$) cubes are efficiently glued block after being produced via cast polymerization, enable rapid cost-efficient detector construction. This work could become particularly relevant next-generation long-baseline neutrino-oscillation DUNE, Hyper-Kamiokande ESSnuB.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A large area plastic scintillator detector array for fast neutron measurements

A large area plastic scintillator detector array(∼ 1×1 m) has been set up for fast neutron spectroscopy at the BARC-TIFR Pelletron laboratory, Mumbai. The energy, time and position response has been measured for electrons using radioactive sources and for mono-energetic neutrons using the 7Li(p,n1) Be*(0.429 MeV) reaction at proton energies between 6.3 and 19 MeV. A Monte Carlo simulation of th...

متن کامل

Technical Note: Out‐of‐field dose measurement at near surface with plastic scintillator detector

Out-of-field dose depends on multiple factors, making peripheral dosimetry com-plex. Only a few dosimeters have the required features for measuring peripheral dose. Plastic scintillator dosimeters (PSDs) offer numerous dosimetric advantages as required for out-of-field dosimetry. The purpose of this study is to determine the potential of using PSD as a surface peripheral dosimeter. Measurements...

متن کامل

Development of a liquid scintillator-based 3D detector for range measurements of spot-scanned proton beams

The goal of the present study is to develop a liquid scintillator-based 3D detector and investigate its performance for beam range measurements in real time. The detector design consists of a tank filled with water-equivalent liquid scintillator that scintillates in response to incident proton beams. Three scientific complementary metal-oxide semiconductor (sCMOS) cameras collect the resulting ...

متن کامل

Determination of oil reservoir radiotracer (S14CN-) in a single step using a plastic scintillator extractive resin.

The analysis of radiotracers is important in the study of oil reservoir dynamics. One of the most widely used radiotracer is S(14)CN(-). Prior to activity measurements by Liquid Scintillation (LS), routine determinations require the pretreatment steps of purification and concentration of the samples using anion exchange columns. The final elution media produces samples with high salt concentrat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Instrumentation

سال: 2021

ISSN: ['1748-0221']

DOI: https://doi.org/10.1088/1748-0221/16/12/p12010