Dephosphorization of Molten High Chromium Steel with CaC<SUB>2</SUB>-CaF<SUB>2</SUB>Flux

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vibration Damping of High-Chromium Ferromagnetic Steel

The aim of the present work is to study the effect of annealing on the vibration damping capacity of high-chromium (16%) ferromagnetic steel. The alloys were prepared from raw materials of 99.9% purity melted in a high frequency induction furnace under high vacuum. The samples were heat-treated in vacuum at various temperatures (800 to 1200oC) for 1 hour followed by slow cooling (120oC/h). The ...

متن کامل

EFFECT OF HIGH TEMPERATURE OXIDATION ON THE CORROSION BEHAVIOR OF ALUMINIZED LOW CARBON STEEL IN MOLTEN ALUMINUM

Hot dip aluminizing was carried out on the low carbon steel rod under optimized conditions. The aluminized samples were further oxidized at 1000̊C in air atmosphere at two different times of 20 and 60 minutes. Microstructure study and phase analysis were studied by scanning electron microscopy and X-ray diffraction methods, respectively. The characterization of the coating showed that, Fe2...

متن کامل

Removal of MnS inclusions in molten steel using electropulsing

A method using electropulsing to separate inclusions from molten steel is developed, based on the differences in electrical properties between the inclusions and liquid metal. The inclusions have different electrical resistivity from that of the liquid steel and hence being expelled to the surface of the metal by electropulsing. In comparison with the as-solidified untreated steel, the size of ...

متن کامل

High-pressure Injection Injury with Molten Aluminum

INTRODUCTION A previously healthy 65-year-old male presented to the emergency department complaining of a burn to his right forearm. Just prior to arrival the patient was working at a tool and die company casting products with molten aluminum where he inadvertently caused his injury. Physical examination revealed a burn to the right forearm of varying degrees of severity. A non-painful charred ...

متن کامل

The development of advanced creep constitutive equations for high chromium steel P91at low stress range

Diffusion dominates the creep deformation at low stress range for high chromium steel P91. Brittle creep fracture is caused by cavity nucleation, growth and coalescence of cavities and large precipitates (Laves phase and M23C6) at grain boundary under low stress range. At low stress range, a linear relation between strain at failure and different stresses has been described. Moreover, the minim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Tetsu-to-Hagane

سال: 1979

ISSN: 0021-1575,1883-2954

DOI: 10.2355/tetsutohagane1955.65.8_1167