Depth-Adjustable Fixation of External Ventricular Drains to Counteract Obstruction in Tight Ventricles -Technical Note-

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

External ventricular drains: Management and complications

BACKGROUND Insertion of an External Ventricular Drain (EVD) is arguably one of the most common and important lifesaving procedures in neurologic intensive care unit. Various forms of acute brain injury benefit from the continuous intracranial pressure (ICP) monitoring and cerebrospinal fluid (CSF) diversion provided by an EVD. After insertion, EVD monitoring, maintenance and troubleshooting ess...

متن کامل

Hybrid external fixation via a minimally invasive method for tibial pilon fractures ​– Technical note

INTRODUCTION We aimed to present the clinical and radiological outcomes of patients with tibial pilon fractures who were treated with hybrid external fixators. Shanz screws were applied synchronously and used as joysticks for fracture reduction. Radiological evaluations were conducted on roentgenograms at the second week, sixth week, third month and first year. MATERIAL AND METHODS The study ...

متن کامل

Effect of Material Wet on Silo Obstruction Solution by Impact (TECHNICAL NOTE)

Vertical silos are large cylinders used for material storage in agriculture and mineral industries. One of the silo problems is its obstruction due to dome and dense packing. Depend on the material properties and silo dimensions several techniques are used to solve this problem. In the present work, possibility of obstruction solution of a laboratory silo by ball impact is investigated. Test ma...

متن کامل

Glow Discharge Depth Profiling a Powerful Analytical Technique in Surface Engineering (TECHNICAL NOTE)

A variety of analytical techniques have been developed and employed to characterize the surfaces, subsurfaces and interfaces of surface engineering systems. They provide important information for quality control, process optimization and further development. Since the mid 1980's, glow discharge spectrometry (GDS) has emerged as an important and versatile technique for rapid depth profiling anal...

متن کامل

Tension band wire for acetabular fracture fixation: a technical note.

Maintaining reduction of an acetabular fracture during internal fixation is difficult. A variety of clamps can be used to facilitate reduction, but they are cumbersome and may damage the sciatic nerve. We developed a simple and cost-effective technique for provisional reduction and fixation of acetabular fractures using 2 screws and a tension band wire.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Neurologia medico-chirurgica

سال: 2010

ISSN: 0470-8105,1349-8029

DOI: 10.2176/nmc.50.611