Design and Characterization of a Helium-Discharge Ionization Detector for Gas Chromatography.
نویسندگان
چکیده
منابع مشابه
A surface ionization detector for capillary gas chromatography.
A novel surface ionization detector using a reducing quartz liner and a Mo emitter with a quartz enclosed internal heater for selective measurement of alkylamines by gas chromatography is designed and evaluated.
متن کاملinvestigating the feasibility of a proposed model for geometric design of deployable arch structures
deployable scissor type structures are composed of the so-called scissor-like elements (sles), which are connected to each other at an intermediate point through a pivotal connection and allow them to be folded into a compact bundle for storage or transport. several sles are connected to each other in order to form units with regular polygonal plan views. the sides and radii of the polygons are...
Evaluation of the pulsed discharge helium ionization detector for the analysis of hydrogen and methane in breath.
Under the appropriate separation conditions the pulsed discharge helium ionization detector (PDHID) was used to detect hydrogen and methane separated from the matrix components of human breath samples. The sensitivity of this method is over an order of magnitude better than published methods using a flame ionization detector (FID) and a thermal conductivity detector (TCD), and has the further a...
متن کاملAcoustic flame detector for gas chromatography.
A novel gas chromatography detector is described that uses acoustic signals from a partly premixed hydrogen-air flame burning on top of a capillary. The device, referred to as the acoustic flame detector (AFD), is based on the measurement of the frequency of acoustic transients generated at the burner under a range of operating conditions. The presence of trace amounts of analyte in the flame w...
متن کاملFast gas chromatography of explosive compounds using a pulsed-discharge electron capture detector.
The detection of a mixture of nine explosive compounds, including nitrate esters, nitroaromatics, and a nitramine in less than 140 sec is described. The new method employs a commercially available pulsed-discharge electron capture detector (PDECD) coupled with a microbore capillary gas chromatography (GC) column in a standard GC oven to achieve on-column detection limits between 5 and 72 fg for...