Design and Implementation of 85dB CMRR, 4.2 MHz CMOS Instrumentation Amplifier for Bio-Electric Signals

نویسندگان

چکیده

This paper presents the design and Implementation of a novel CMOS Instrumentation Amplifier using capacitive neutralization feedback transconductance techniques for bioelectric signal enhancement. The proposed amplifier also implements indirect current feedback, operating at 3-volt supply. With compact footprint 0.062mm² on chip, achieves an impressive bandwidth 4.2MHz 85 dB CMRR. Implemented 0.25μm technology, showcases notable characteristics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of High CMRR Instrumentation Amplifier for Biomedical Systems

This paper describes an instrumentation amplifier (INA) with three operational amplifier (op amp) topology, for biomedical applications. To achieve low offset new circuit technique is achieved by adding NMOS transistor and two phase clock scheme with a frequency of 20 KHz. With the unity gain bandwidth of 92 KHz , the open loop gain of this instrumentation amplifier is found to be 50 dB and hav...

متن کامل

ANALYSIS AND DESIGN OF HIGH CMRR INSTRUMENTATION AMPLIFIER FOR ECG SIGNAL ACQUISITION SYSTEM USING 180nm CMOS TECHNOLOGY

This paper describes the design of Current Mode Instrumentation Amplifier (CMIA) for ECG signal Acquisition system. The CMIA topology is based on voltage mode operational amplifier (op-amp) power supply current sensing technique. Op amp mismatch and precise current mirrors are two design challenges of this topology. High Common Mode Rejection Ratio (CMRR) and Power Supply Rejection Ratio PSRR i...

متن کامل

development and implementation of an optimized control strategy for induction machine in an electric vehicle

in the area of automotive engineering there is a tendency to more electrification of power train. in this work control of an induction machine for the application of electric vehicle is investigated. through the changing operating point of the machine, adapting the rotor magnetization current seems to be useful to increase the machines efficiency. in the literature there are many approaches wh...

15 صفحه اول

Voltage- and current-controlled high CMRR instrumentation amplifier using CMOS current conveyors

A new approach to the design of an instrumentation amplifier using only 2 CMOS current-controlled conveyors and an active resistor is introduced. The new approach, which has no passive components, offers a wide bandwidth and a high common-mode rejection ratio (CMRR). Electronically controllable gain by voltage and current is also obtained by this new circuit. The circuit is simulated using the ...

متن کامل

To Design High CMRR, High Slew rate Instrumentation Amplifier using OTA and CDTA for Biomedical Application

In today’s world operational amplifier is used in lot of application. The techniques for achieving high slew rate and high CMRR is by cascading the transistors. This paper focus is on understanding of Operational Trans conductance Amplifier (OTA) and Current Differencing Trans conductance Amplifier (CDTA) with its application as Instrumentation Amplifier (IA) for Biomedical application. We have...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: SSRG international journal of electrical and electronics engineering

سال: 2023

ISSN: ['2348-8379', '2349-9176']

DOI: https://doi.org/10.14445/23488379/ijeee-v10i8p119