Design and Implementation of a pH Sensor for Micro Solution Based on Nanostructured Ion-Sensitive Field-Effect Transistor

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

fabrication of new ion sensitive field effect transistors (isfet) based on modification of junction-fet for analysis of hydronium, potassium and hydrazinium ions

a novel and ultra low cost isfet electrode and measurement system was designed for isfet application and detection of hydronium, hydrazinium and potassium ions. also, a measuring setup containing appropriate circuits, suitable analyzer (advantech board), de noise reduction elements, cooling system and pc was used for controlling the isfet electrode and various characteristic measurements. the t...

Ion-sensitive field effect transistor as a pH sensor.

In this work, both the static and dynamic behaviors as well as the signal read-out circuits of ISFETs were studied. The standard NMOS structure in conjunction with the insulator-electrolyte capacitor was used to model the ISFET under study. The site-binding theory was incorporated to describe the chemistry occurring at the insulator/electrolyte interface. The mechanism of the threshold voltage ...

متن کامل

The ion sensitive field effect transistor (ISFET) pH electrode: a new sensor for long term ambulatory pH monitoring.

Intraluminal pH monitoring in man should be performed with disposable multichannel assemblies that allow recordings at multiple sites and prevent transmission of infection. Currently available glass electrodes are unsuitable for this purpose because of their size and price. We have thus constructed and tested a small, combined ion sensitive field effect transistor (ISFET) pH electrode incorpora...

متن کامل

Potassium Ion-Sensitive Field Effect Transistor

was readily constructed by simple modification of a common FID hydrocarbon monitor, with addition of a commercially available valve oven, switching valve, and timer. This system, except for the adjusted response time, had virtually the same operating specifications as the original hydrocarbon analyzer. Short-term studies indicated the system was practical, reliable, and accurate. Air-monitoring...

متن کامل

A highly pH-sensitive nanowire field-effect transistor based on silicon on insulator

BACKGROUND An experimental and theoretical study of a silicon-nanowire field-effect transistor made of silicon on insulator by CMOS-compatible methods is presented. RESULTS A maximum Nernstian sensitivity to pH change of 59 mV/pH was obtained experimentally. The maximum charge sensitivity of the sensor was estimated to be on the order of a thousandth of the electron charge in subthreshold mod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Sensors

سال: 2020

ISSN: 1424-8220

DOI: 10.3390/s20236921