Design and Performance of Heat Pipe Air-Conditioning Based on Latent Heat of Water Evaporation

نویسندگان

چکیده

This paper proposes a scheme for creating low-pressure environment to evaporate large amount of water, using the latent heat water evaporation cooling, designing and building test bench pipe air conditioning system, testing working performance negative pressure evaporating conditioner at 30–85°C. COMSOL Multiphysics Establish fluid transfer model analyze internal transfer. Under design condition 40°C, EER is 2.1 cooling capacity 298W. The experimental data results show that system in high-efficiency range 50–75°C 2.5, maximum 376W, actual application temperature 30–40°C 1.4, 221.6W. Basically reached index can run stably.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology

The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...

متن کامل

Passive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate

Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...

متن کامل

Apparent latent heat of evaporation from clothing: attenuation and "heat pipe" effects.

Investigating claims that a clothed person's mass loss does not always represent their evaporative heat loss (EVAP), a thermal manikin study was performed measuring heat balance components in more detail than human studies would permit. Using clothing with different levels of vapor permeability and measuring heat losses from skin controlled at 34 degrees C in ambient temperatures of 10, 20, and...

متن کامل

Experimental Investigation on CuO/Water Nanofluid Effect on the Heat Transfer Rate of Heat Pipe Network

In this study, a new configuration of heat pipes as Heat Pipe Network is introduced. Here, the heat pipe network is designed, constructed and then has been under the performance assessment. This heat pipe network consists of 4 vertical heat pipes connected to evaporator collector from bottom and condenser collector from top. In order to investigate the effect of nanofluids on the thermal effici...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Advances in transdisciplinary engineering

سال: 2022

ISSN: ['2352-751X', '2352-7528']

DOI: https://doi.org/10.3233/atde220056