Design, fabrication, and high-gradient testing of X -band choke-mode damped structures
نویسندگان
چکیده
منابع مشابه
Experimental High-gradient Testing of an Elliptical-rod Photonic Band-gap (pbg) Structure at X-band
An 11.4 GHz photonic band-gap (PBG) structure where the rods in the inner row have an elliptical cross-section has been designed at MIT and manufactured and tested at high power and high repetition rate at SLAC. This structure exhibits lower surface magnetic fields on the rods relative to previous PBG structures tested at SLAC, which reduces the ohmic heating of the rod surface in an effort to ...
متن کاملDesign and Simulation of an X Band LC VCO
In this paper, a systematic method for the circuit parameters design of a monolithic LC Voltage Controlled Oscillator (VCO) is reported. The method is based on the negative resistance generation technique. As a result, a VCO has been designed in 0.18um CMOS technology using a conventional VCO structure to obtain the optimum values for the phase noise and power consumption. The simulation result...
متن کاملDesign of X Band High Power Amplifier MMIC Based on AlGaN/GaN HEMT
In this paper, we have presented an X band high power amplifier based on MMIC (Monolithic Microwave Integrated Circuit) technology for satellite remote sensing systems. We have used GaN HEMT process with 500 nm gate length technology with VD= 40 V and VG= -2 V in class E structure. The proposed two-stage power amplifier provides 25 dB power gain with maximum output power of 49.3 dBm at 10 GHz. ...
متن کاملSlac High Gradient Testing of a Kek X-band Accelerator Structure
The high accelerating gradients required for future linear colliders demands a better study of field emission and RF breakdown in accelerator structures. Changes in structure geometry, vacuum pumping, fabrication methods, and surface finish can all potentially impact the conditioning process, dark current emission, and peak RF power handling capability. Recent tests at SLAC of KEK’s “M2” travel...
متن کاملDamping Effect Studies for X-band Normal Conducting High Gradient Standing Wave Structures*
The Multi-TeV colliders should have the capability to accelerate low emittance beam with high rf efficiency, X-band normal conducting high gradient accelerating structure is one of the promising candidate. However, the long range transverse wake field which can cause beam emittance dilution is one of the critical issues. We examined effectiveness of dipole mode damping in three kinds of X-band,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physical Review Accelerators and Beams
سال: 2019
ISSN: 2469-9888
DOI: 10.1103/physrevaccelbeams.22.031001