Design Methodology and Optimization of a Medium-Frequency Transformer for High-Power DC–DC Applications
نویسندگان
چکیده
منابع مشابه
Medium Frequency Transformer Design and Optimization
This paper describes the technical challenges tied to modeling and design optimization of the medium frequency transformer (MFT) for power electronic applications, namely emerging solid state transformers (SSTs). A detailed analysis and modeling of the phenomena governing the MFT electrical behavior as well as limiting the operation and design range is performed. A synthesis of all these models...
متن کاملFlexible Power Electronic Transformer for Power Flow Control Applications
This paper proposes a Flexible Power Electronic Transformer (FPET) for the application in the micro-grids. The low frequency transformer is usually used at the Point of Common Coupling (PCC) to connect the low voltage grid and utility network to each other. The conventional 50Hz transformer results in enhanced low voltage-grid power management system during grid-connected operation. In this pap...
متن کاملElectric Field Simulations and Analysis for High Voltage High Power Medium Frequency Transformer
The electronic power transformer (EPT) raises concerns for its notable size and volume reduction compared with traditional line frequency transformers. Medium frequency transformers (MFTs) are important components in high voltage and high power energy conversion systems such as EPTs. High voltage and high power make the reliable insulation design of MFT more difficult. In this paper, the influe...
متن کاملOptimum Design of a High-Power, High-Frequency Transformer - Power Electronics, IEEE Transactions on
A procedure for optimum design of a high-power, high-frequency transformer is PresentedThe Procedure is based on both electrical and thermal processes in the transformer and identifies a) the VA-rating of ferrite cores in relation to the operating frequency, , , ) the optimum flux density in the core, and c) the optimum current densities of the windings providing maximum transformer efficiency....
متن کاملA High Frequency Transformer Winding Model for FRA Applications
Frequency response analysis (FRA) is a method which is used to detect mechanical faults in transformers. The FRA response of a transformer is determined by its geometry and material properties, and it can be considered as the transformer’s fingerprint. If there are any mechanical changes in the transformer, for example if the windings are moved or distorted, its fingerprint will also be changed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Industry Applications
سال: 2016
ISSN: 0093-9994,1939-9367
DOI: 10.1109/tia.2016.2582825