Design of shunt hybrid active power filter (SHAPF) to reduce harmonics in AC side due to Non-linear loads

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of a Shunt Active Power Filter to Compensate Multiple Non-linear Loads

In this paper, the implementation of a shunt active power filter with a small series reactor for a three-phase system is presented. The system consists of multiple non-linear loads, which are a combination of harmonic current sources and harmonic voltage sources, with significant unbalanced components. The filter consists of a three-phase current-controlled voltage source inverter (CC-VSI) with...

متن کامل

Mitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach

This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...

متن کامل

Active Power Filter Techniques for Harmonics Suppression in Non Linear Loads

the growth in electronic devices applications increasing the non linear loads in power systems because most of these devices involve uses regulated power supply such as SMPS, Choppers etc. but because of the non linearity involved with the controlling process it produces undesired harmonics and reactive components which causes the heating, vibration electromagnetic interference etc. hence to mi...

متن کامل

On the AC-Side Interface Filter in Three-Phase Shunt Active Power Filter Systems

The proper selection of the AC-side passive filter interconnecting the voltage source converter to the power supply is essential to obtain satisfactory performances of an active power filter system. The use of the LCL-type filter has the advantage of eliminating the high frequency switching harmonics in the current injected into the power supply. This paper is mainly focused on analyzing the in...

متن کامل

Analysis of Flying Capacitor Multilevel Inverter Based Shunt Active Power Filter to Voltage Deregulation of Non Linear Loads

This paper main intents to present a flying capacitor multilevel inverter based shunt active power filter(APF) with Sigma-Delta modulation. A multilevel Sigma-Delta modulation(SDM) control can be applied to control power section of APF intention to reducing sensitivity to flying capacitor voltage deregulation and mending modulator performance. In these control section of APF perfect harmonic ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Power Electronics and Drive Systems (IJPEDS)

سال: 2018

ISSN: 2088-8694,2088-8694

DOI: 10.11591/ijpeds.v9.i4.pp1926-1936