Detection of biological thiols based on a colorimetric method
نویسندگان
چکیده
منابع مشابه
A colorimetric and fluorescent merocyanine-based probe for biological thiols.
A new "dual-mode" chromogenic and fluorescent turn-on probe (2) for the selective sensing of biological thiols is reported. In MeOH-H(2)O cosolvent at physiological pH 7.40 (MeOH-H(2)O = 3:7), biological thiols cleave the 2,4-dinitrobenzenesulfonyl group to release the chromo- and fluorophore merocyanine (3).
متن کاملColorimetric detection of thiols using a chromene molecule.
A new thiol-containing colorimetric probe has been developed by using a chromene derivative, 7-nitro-2,3-dihydro-1H-cyclopenta[b]chromen-1-one (1). The molecule exhibited high selectivity and sensitivity for detecting thiol species as cysteine, homocysteine, and glutathione in aqueous solution through a rapid visual color change from colorless to yellow.
متن کاملA gold nanoparticle/latex microsphere-based colorimetric oligonucleotide detection method*
An exceptionally simple and effective DNA detection methodology based on latex microsphere and gold nanoparticle probes has been developed. The latex and gold particle probes, which were functionalized with separate oligonucleotide sequences, undergo hybridization in the presence of target strands that are complementary to both of the probes. Duplex formation thus results in linking of gold nan...
متن کاملSpiropyran as a reusable chemosensor for selective colorimetric detection of aromatic thiols.
Design of optical molecular probes for selective detection of aromatic thiols has attracted much attention. Although several types of probes have been proposed, all of them exhibit colorimetric or fluorometric response via irreversible reaction with aromatic thiols and cannot be reused. Here we report that a spiropyran dye is the first example of a reusable chemosensor for aromatic thiols. A co...
متن کاملDamage Detection of Axially Loaded Beam: A Frequency-Based Method
The present study utilizes an analytical method to formulate the three lowest modal frequencies of axially-loaded notched beam through both crack location and load level in a specific format that can be used in existing frequency-based crack-identification methods. The proposed formula provides a basis to shift into two states, one with axial loading and the other without any loading whatsoever...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Zhejiang University-SCIENCE B
سال: 2016
ISSN: 1673-1581,1862-1783
DOI: 10.1631/jzus.b1500232