Detection of endograft fractures with multidetector row computed tomography

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of endograft fractures with multidetector row computed tomography.

Delayed endograft metallic strut failures detected in vivo with multidetector row computed tomography (MDCT) are reported in two patients who underwent endovascular abdominal aortic aneurysm repair with AneuRx and Talent endografts. In both instances, nitinol fractures were associated with proximal migration and type I endoleak. In both cases, the metallic strut fractures were detected with tra...

متن کامل

Multidetector-Row Computed Tomography Coronary Angiography

onsiderable progress has recently been achieved in the field of noninvasive imaging of the coronary arteries by computed tomography (CT). Multidetector-row CT (MDCT) scanners are equipped with thinner detectors and have a shorter rotation time, which enables considerably faster volume coverage with a thinner slice width during a single breath hold. The entire heart volume can be covered with ne...

متن کامل

Multidetector computed tomography in acute joint fractures.

Conventional radiography plays an essential diagnostic role in the primary evaluation of acute joint trauma. In complex fractures, however, computed tomography (CT) is an imaging modality often used second to radiography. As a result of technical breakthroughs in the field, multidetector CT (MDCT) allows faster imaging and better temporal, spatial, and contrast resolution compared with conventi...

متن کامل

Multidetector-row computed tomography management of acute pulmonary embolism.

BACKGROUND The purpose of this study was to evaluate the usefulness and safety of multidetector-row computed tomography (MDCT) pulmonary angiography and indirect venography management of acute pulmonary embolism (PE), including indication for inferior vena cava (IVC) filter. METHODS AND RESULTS Seventy-one consecutive patients who were clinically suspected of PE and underwent 16-slice MDCT pu...

متن کامل

Non-invasive detection and assessment of coronary artery disease with multidetector-row computed tomography.

The fast volume coverage of retrospective ECG-gated multidetector-row helical CT(MDCT)arrows for acquisition of the entire heart volume with nearly isotropic spatial resolution(0.5×0.5×0.6 mm)within a single breath-hold. The sub-millimeter spatial resolution enables depiction of the major and also of peripheral coronary artery segments with lumen diameter down to 1 mm. The results of studies of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Vascular Surgery

سال: 2005

ISSN: 0741-5214

DOI: 10.1016/j.jvs.2005.07.009