Determination of Bromide Ion Concentration in Urine Using a Head-space Gas Chromatography and an Ion Chromatography

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of trans octadecenoic acids by silver-ion chromatography-gas liquid chromatography: an intercomparison of methods.

Several silver-ion chromatography-gas liquid chromatography (GLC) techniques for the determination of trans octadecenoic acids in partially hydrogenated vegetable fats were collaboratively evaluated. Twelve laboratories participated in the study. All collaborators used high polarity fused silica capillary columns for the separation of fatty acid methyl esters by GLC; 7 collaborators isolated tr...

متن کامل

Determination of iodide in seawater by capillary ion chromatography using hexadimethrine bromide modified C30 stationary phases.

A novel and simple capillary ion chromatographic method for the determination of iodide is reported. Separation was achieved on a laboratory-made packed capillary column (100 mm × 0.32 mm i.d.) packed with triacontyl-functionalized silica, followed by a modification with hexadimethrine bromide, where 1 mM sodium chloride-acetonitrile (95:5, v/v) was used as the eluent and UV-absorbing analyte ...

متن کامل

Analysis of methylbenactyzium bromide in human urine by thin-layer chromatography and pyrolysis gas chromatography.

A rapid and simple method of utilizing thin-layer chromatography (TLC) and pyrolysis gas chromatography (PyGC) for the identification and determination of methylbenactyzium bromide in human urine was studied in this report. Methylbenactyzium bromide was extracted from urine with ODS-cartridge (Sep-Pak C18), then spotted onto a silica gel 60 F254 TLC plate. After development, the separated spot ...

متن کامل

Development and Validation of an Ion Chromatography Method for Quantification of Ammonium Ions in STEALTH® Liposomes

Ammonium sulfate is one of the subsidiary components in the stealth liposome structure. The ratio of ammonium ion bound to liposome sphere to ammonium ions outside the liposome plays an important role in drug delivery formulation; accordingly, in order to quantify the ammonium ion in the liposome structure, a rapid and sensitive method was validated using a conductivity detector. Through this m...

متن کامل

Determination of Hexavalent Chromium in Drinking Water Using Ion Chromatography

INTRODUCTION Hexavalent chromium, Cr(VI), is the most toxic form of the metal chromium, a primary drinking water contaminant in the U.S. Dissolved hexavalent chromium can be determined as chromate (CrO 4 ) by ion chromatography in drinking water, groundwater, and industrial wastewater effluents as described in U.S. EPA Method 218.6 and Dionex Technical Note 26. Dionex Technical Note 26 uses a 2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of UOEH

سال: 1991

ISSN: 0387-821X,2187-2864

DOI: 10.7888/juoeh.13.19