Determination of Elements in Thermal Springs for Monitoring Pre-Earthquake Activites by ICP-MS
نویسندگان
چکیده
منابع مشابه
Determination of Actinide Elements in Environmental Samples by Icp-ms
DETERMINATION OF ACTINDE ELEMENTS iN ENVIRONMENTAL SAMPLES BY ICP-MS Jason Bedford Truscott Methods for the determination of the actinide elements m water, biological, soil and sediment samples have been developed usmg on-line sohd phase extraction and high performance liquid chromatography (I{PLC) coupled with mductively coupled plasma mass spectrometry (ICP-MS) Initial applications utilised a...
متن کاملsuppression of coke formation in thermal cracking by coke inhibitors
the main purpose of this research was to:1.develop a coking model for thermal cracking of naphtha.2.study coke inhibition methods using different coke inhibitors.developing a coking model in naphtha cracking reactors requires a suitable model of the thermal cracking reactor based on a reliable kinetic model.to obtain reliable results all these models shall be solved simultaneously.for this pu...
15 صفحه اولDetermination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS
The relatively recent technology of collision/reaction cell (CRC) has become widely used with quadrupole ICP-MS (ICP-QMS) to remove polyatomic ions, which can cause problematic spectral interferences on analytes in complex matrices. By utilizing CRC, background equivalent concentrations (BECs) can be reduced to the ppt or sub-ppt level for almost all elements in semiconductor grade chemicals. I...
متن کاملSimultaneous determination of trace elements in minute samples by electrothermal-vaporization/low-pressure helium-ICP-MS.
Electrothermal vaporization with two filaments was studied for low-pressure helium-ICP-MS. A 10-microl volume of sample was dried and vaporized, and then introduced to the ICP. With this technique, four elements were simultaneously determined with the acceptable precisions (RSD ca. 10%). The detection limit based on 3sigma of background signals approached the fractional ppb range. The proposed ...
متن کاملDetermination method of multi elements in ferromanganese samples by LA-ICP-MS.
A dilution method using MnO(2) for the manganese nodule standard, JMn1, has been newly adopted to obtain accurate calibration lines. Moreover, an internal standard correction method was applied to correct changes in the sample introduction efficiency for the prime purpose of laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) analysis. Using the dilution method and the cor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Atomic Spectroscopy
سال: 2011
ISSN: 0195-5373,2708-521X
DOI: 10.46770/as.2011.05.002