Determination of fenitrothion in commercial formulations by square wave voltammetry and UV-Vis spectroscopy
نویسندگان
چکیده
منابع مشابه
Determination of Fenitrothion in Commercial Formulations by Square Wave Voltammetry and UV-Vis Spectroscopy
A voltametria de onda quadrada foi utilizada com o eletrodo de gota suspensa de mercúrio para determinar o conteúdo de Fenitrothin em três diferentes formulações comerciais. Em princípio, as determinações de Fenitrothion foram feitas em uma solução tampão BR (pH 10,5) preparada com água pura. Nestas soluções, os limites de determinação e quantificação encontrados foram 5,20x10 μmol L (1,44 ppb)...
متن کاملDetermination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods
In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...
متن کاملDetermination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods
In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...
متن کاملElectrochemical determination of closantel in the commercial formulation by square-wave adsorptive stripping voltammetry
ABSTRACT In this paper, the square-wave adsorptive stripping voltammetric (SWAdSV) determination of the veterinary drug closantel using a renewable silver amalgam film electrode (Hg(Ag)FE) is presented. As observed in SWAdSV, closantel provided one well-shaped reduction peak suitable for analytical purposes at potential ca. -1.4 V in the Britton-Robinson (B-R) buffer at pH 7.0. At optimal condi...
متن کاملDetermination of clopidogrel using square wave voltammetry
The determination of clopidogrel, an antiplatelet agent, was performed at a gold electrode in pH 3.7 acetate buffer using cyclic voltammetry (CV) and square wave voltammetry (SWV). Each voltammogram was characterized by the well defined peak at approximately 1.0 V. The current of anodic stripping peak exhibited a linear dependence on the clopidogrel concentration in the range from 317.89 to 935...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Brazilian Chemical Society
سال: 2005
ISSN: 0103-5053
DOI: 10.1590/s0103-50532005000500011