Determination of fenitrothion in commercial formulations by square wave voltammetry and UV-Vis spectroscopy

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Fenitrothion in Commercial Formulations by Square Wave Voltammetry and UV-Vis Spectroscopy

A voltametria de onda quadrada foi utilizada com o eletrodo de gota suspensa de mercúrio para determinar o conteúdo de Fenitrothin em três diferentes formulações comerciais. Em princípio, as determinações de Fenitrothion foram feitas em uma solução tampão BR (pH 10,5) preparada com água pura. Nestas soluções, os limites de determinação e quantificação encontrados foram 5,20x10 μmol L (1,44 ppb)...

متن کامل

Determination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods

In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...

متن کامل

Determination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods

In this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containin...

متن کامل

Electrochemical determination of closantel in the commercial formulation by square-wave adsorptive stripping voltammetry

ABSTRACT In this paper, the square-wave adsorptive stripping voltammetric (SWAdSV) determination of the veterinary drug closantel using a renewable silver amalgam film electrode (Hg(Ag)FE) is presented. As observed in SWAdSV, closantel provided one well-shaped reduction peak suitable for analytical purposes at potential ca. -1.4 V in the Britton-Robinson (B-R) buffer at pH 7.0. At optimal condi...

متن کامل

Determination of clopidogrel using square wave voltammetry

The determination of clopidogrel, an antiplatelet agent, was performed at a gold electrode in pH 3.7 acetate buffer using cyclic voltammetry (CV) and square wave voltammetry (SWV). Each voltammogram was characterized by the well defined peak at approximately 1.0 V. The current of anodic stripping peak exhibited a linear dependence on the clopidogrel concentration in the range from 317.89 to 935...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Brazilian Chemical Society

سال: 2005

ISSN: 0103-5053

DOI: 10.1590/s0103-50532005000500011