Determination of Mefenamic Acid in Aqueous Solutions Using Reverse - Continuous Flow Injection Analysis

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal and reverse flow injection–spectrophotometric determination of thiamine hydrochloride in pharmaceutical preparations using diazotized metoclopramide

Simple and sensitive normal and reverse flow injection methods for spectrophotometric determination of thiamine hydrochloride (THC) at the microgram level were proposed and optimized. Both methods are based on the reaction between THC and diazotized metoclopramide in alkaline medium. Beer's law was obeyed over the range of 10-300 and 2-90 μg/mL, the limits of detection were 2.118 and 0.839 μg/m...

متن کامل

Determination of ethanol using flow injection enthalpimetry.

A flow injection enthalpimetric method for the determination of ethanol in fuel-grade ethanol, based on the heat of dilution of ethanol, is described. The accuracy and precision were 0.05% of ethanol; interferences by several substances are discussed. A similar procedure was also applied to the determination of ethanol in wines and spirits after distillation, yielding a precision of 0.0%0.1% of...

متن کامل

Permanganate-based chemiluminescence analysis of ferulic acid using flow injection.

A simple, sensitive and rapid flow-injection chemiluminescence method has been developed for the determination of ferulic acid based on the chemiluminescence reaction of ferulic acid with potassium permanganate in a nitric acid medium. A strong chemiluminescence signal was observed when ferulic acid was injected into an acidic potassium permanganate solution in a flow-cell. The present method a...

متن کامل

Methylene blue removal from aqueous solutions by electrocoagulation in continuous flow reactor: Modeling and optimization of operating parameters

Introduction The application and increasingly produce of colorants, particularly, synthetic dyes, are one of the main environmental and health concerns especially in industrialized countries. If this type of dyes is discharged into the environment without any control, many problems will arise. Therefore, it is necessary to remove the dyes from aqueous solutions using appropriate methods. The p...

متن کامل

Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine

A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Pharmaceutical Negative Results

سال: 2022

ISSN: ['0976-9234', '2229-7723']

DOI: https://doi.org/10.47750/pnr.2022.13.03.026